Troubleshooting guide

25
Reference Manual
00809-0100-4308, Rev BA
Section 3: Installation
December 2014
Installation
Coaxial probe
1. Mark where to cut the probe.
2. Insert the centering piece.
(The centering piece is delivered
from factory and should be used to
prevent the spacers centering the
rod from coming loose).
3. Cut the tube to the desired length.
4. Move the centering piece.
5. Cut the rod inside the tube. Make
sure the rod is fixed with the
centering piece while cutting.
Pipes longer than 49 in. (1250
mm) can be shortened by as
much as 23.6 in. (600 mm).
Pipes shorter than 49 in. (1250
mm) can be cut as long as the
remaining length is not less
than 15.7 in. (400 mm).
Centering piece
Maximum shortening 23.6
in. (600 mm)
> 49 in.
(1250 mm)
Minimum probe length
15.7 in. (400 mm)
49 in.
(1250 mm)