Troubleshooting guide

178
Reference Manual
00809-0100-4308, Rev BA
Appendix D: Configuration Parameters
December 2014
Configuration Parameters
Advanced
Peak Detection Method Select which peak detection to use for level measurements.
For furter information on when to use the peak detection
method, see section “Resolving thin oil layers” on page 91.
Near Zone Compensation Improves measurement performance in the zone close to the
device by compensating for probe dependent echo signature
or recorded echo signature.
If Near Zone Compensation is disabled, neither the probe
dependent compensation nor the compensation due to Trim
Near Zone will be used by the device.
Echo Search Window Select window mode to use for the echo tracking function.
Value typically provided by manufacturer.
Window Size Window size used by echo tracking function. Window Size
can only be changed when the Eco Search Window mode is
set to User Defined. Value typically provided by
manufacturer.
Gain Factor Index Controls the hardware amplification of the waveform. Value
typically provided by manufacturer.
Calibration Scale Factor Microwave propagation factor to use. Value typically
provided by manufacturer.
Peak Detection
Method
Description
Peak Center Surface detected at the first
amplitude peak closest to device
detected above the Surface
Threshold.
Threshold
Intersection
Surface detected at first
intersection with Surface
Threshold.
Threshold Intersection
Peak Center
Surface Threshold