00809-0100-4308, Rev BA
Appendix A: Reference Data
December 2014
Reference Data
A.6 Dimensional drawings
Figure A-13. Flexible Single Lead Probe
Recommended: D > 4 (100)
Minimum: D=1.5 (38)
(1)
Dimensions are in inches (millimeters).
12 (297.2)
3.9 (100.2)2.8 (71.3)
External antenna
(option WK)
L
56 ft
(17 m)
Ø 0.16 (4): SST probe
Ø 0.28 (7): PTFE covered probe
Ø D (Nozzle diameter)
5.5
(140)
Ø 0.9 (22)
BSP-G 1 in., s52
BSP-G 1½ in., s60
Short weight
(option W2)
2 (50)
Ø 1.5 (38)
Heavy weight
(option W3)
5.5
(140)
Ø 1.5 (38)
Chuck
(option W4)
Ø 1 (24.5)
1 (26)
4.3 (110)
7.8 (198)
Min. 8 (200)
Chamber/pipe
Min. Ø 2 (50)
The probe must be
in the center of the
probe/chamber
PTFE covered probe
and protective plate
Small weight
(option W1)
Weight for PTFE
covered probe
17.1
(435)
Ø 0.88 (22.5)
Thread sealing
NPT 1 in., s52
NPT 1½ in., s52
NPT 2 in., s60
Protective
plate
2.4 (62)
1.9 (47)
2.4 (62)
3.4 (86)
Min. 4 (100) if smooth metallic wall.
Min. 16 (400) if disturbing objects or
rugged metallic wall.
H (Nozzle height)
H < 4 (100) + D
Tri-Clamp
connection
12 (297.2)
4 (100): Standard length
10 (250): Long stud (option LS)
0.6 (15)
(1) The Trim Near Zone (TNZ) function may be
necessary or an Upper Null Zone (UNZ)
setup may be required to mask the nozzle.