Instruction Manual
Instruction Manual
D103803X012
Z500 Valve
April 2015 - rev B
13
Figure 6. Use Packing Flange
8. Bolt up the packing flange. Use Belleville washers in the same orientation as removed. Contact your Emerson
Process Management sales office for additional information. Make sure that the markings on the studs and nuts are
facing out. Tighten the nuts in a star pattern (figure 2). Tighten the nuts with applicable torque (table 5).
Figure 7. Bolt Up the Packing Flange
Actuator Mounting
CAUTION
Never use a hammer or excessive force to install the stem adapter on the valve. Improper installation can cause permanent
damage to the valve.
1. Mount the stem adapter on top of the stem with the two keys. Make sure it fits onto the stem easily without
hammering.
2. Position the mounting bracket onto the body. Use anti-seize lubricant on the bracket studs and nuts. Make sure the
markings on the studs and nuts are facing out. Leave the nuts.