Instruction Manual
Instruction Manual
D102178X012
V260 Valve
September 2012
16
Keys 9* & 17* Sea l Assembly
(1)
VALVE
SIZE, NPS
SEAL PART NUMBER
Key 9 (Outlet) - for dual seal constructions Key 17 (Inlet) - for single and dual seal constructions
PTFE/PEEK POM
(2)
NACE
PTFE/PEEK
NACE POM PTFE/PEEK POM
NACE
PTFE/PEEK
NACE POM
8 28B1218X032 28B1218X012 28B1218X062 28B1218X052 27B1350X032 27B1350X012 27B1350X062 27B1350X052
10 28B1219X032 28B1219X012 28B1219X062 28B1219X052 27B1351X032 27B1351X012 27B1351X062 27B1351X052
12 28B1220X032 28B1220X012 28B1220X062 28B1220X052 27B1352X032 27B1352X012 27B1352X062 27B1352X052
16 37B4961X032 37B4961X012 37B4961X062 37B4961X052 37B4961X032 37B4961X012 37B4961X062 37B4961X052
20 37B5019X032 37B5019X012 37B5019X062 37B5019X052 37B5019X032 37B5019X012 37B5019X062 37B5019X052
24 CL150
& CL300
GE00488X032 GE00488X022 --- --- GE00488X032 GE00488X022 --- ---
24 CL600 GE02813X022 GE02813X012 GE02813X032 GE02813X042 GE02813X022 GE02813X012 GE02813X032 GE02813X042
1. The V260C uses Key 17 in both the inlet and outlet.
2. POM (polyoxymethylene).
Keys 10* & 28* Attenuator Dome, S17400 SST
VALVE VALVE SIZE, NPS
ATTENUATOR DOME PART NUMBER
Key 28 For single seal constructions Key 10 For dual seal constructions
Characterized High Density Characterized High Density
V260A
8 47B1312X012 47B1309X012 48B0916X012 48B0915X012
10 47B1313X012 47B1310X012 48B0918X012 48B0917X012
12 47B1314X012 47B1311X012 48B0920X012 48B0919X012
16 57B4946X012 57B4980X012 57B4982X012 57B4981X012
20 47B4990X012 47B4991X012 47B4992X012 47B4993X012
24 CL150 & CL300 GE39617X012 --- --- ---
24 CL600 GG03694X012 GG03697X012 GG03695X012 GG03696X012
V260B
8 47B3510X012 47B3509X012 48B0922X012 48B0921X012
10 47B3514X012 47B3531X012 48B0924X012 48B0923X012
12 47B3518X012 47B3517X012 48B0988X012 48B0987X012
16 57B4984X012 57B4983X012 57B4986X012 57B4985X012
20 47B5033X012 47B5032X012 47B5031X012 47B5030X012
24 CL150 & CL300 GE00545X012 GE07146X012 GE00699X012 GE07157X012
24 CL600 GG02722X012 GG03691X012 GG02718X012 GG03688X012
*Recommended spare parts
Emerson Process Management
Marshalltown, Iowa 50158 USA
Sorocaba, 18087 Brazil
Chatham, Kent ME4 4QZ UK
Dubai, United Arab Emirates
Singapore 128461 Singapore
www.Fisher.com
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they arenot
to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are
governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such
products at any time without notice.
E 1995, 2012 Fisher Controls International LLC. All rights reserved.
Fisher and ENVIRO-SEAL are marks owned by one of the companies in the Emerson Process Management business unit of Emerson Electric Co. Emerson
Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their
respective owners.
Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance
of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user.