17
Valve-Actuator Dimensions and Weights
See figure 17, table 10, and table 11.
Table 10. Fisher GX 3
-
Way Dimensions and Weights (Standard and HT Constructions)
VALVE
SIZE
TYPE
PORT DIA
ACTUATOR
SIZE
TRAVEL
A B C
Upper Lower
PN10 -
PN40
CL150 CL300
PN10 -
PN40
CL150 CL300 Bonnet
mm mm mm mm mm mm mm mm mm mm
DN 25/
NPS 1
BPC 29 36
225 19 197 184 197 98.5 92 98.5 73
SPC 36 36
DN 40/
NPS
1-1/2
BPC 39 46
225 19 235 222 235 117.5 111 117.5 76
SPC 36 36
DN 50/
NPS 2
BPC 61 70
750 19 267 254 267 133.5 127 133.5 95
SPC 46 46
DN 80/
NPS 3
BPC 78 90
750 38 318 298 318 159 149 159 119
SPC 70 70
DN 100/
NPS 4
BPC 78 90
750 38 368 352 368 184 176 184 119
SPC 90 90
Table 11. Fisher GX 3
-
Way Dimensions and Weights
VALVE SIZE
D (Actuator Height) E F (AR) TOTAL WEIGHT
Std Construction HT Construction Casing Dia
Removal Height
(1)
Std Construction HT Construction
mm mm mm mm kg kg
DN 25/ NPS 1 313 418 270 115 26 30
DN 40/ NPS 1-1/2
313 422 270 115 28 32
DN 50/ NPS 2 342 485 430 120 66 74
DN 80/ NPS 3 395 585 430 145 97 112
DN 100/ NPS 4 395 585 430 145 123 138
1. Clearance required for removing actuator from installed valve body.
STANDARD CONSTRUCTION HT (HIGH TEMPERATURE) CONSTRUCTION
AR
E
D
F
C
B
A/2
A
AR
E
D
F
C
B
A/2
A
F
GE54802
Figure 17. Fisher GX 3
-
Way Dimensions (also see tables 10 and 11)