Instruction Manual
D103414X012 March 2010
Field Communicator Menu Tree - DVC6200f Digital Valve Controller
www.Fisher.com
FIELDVUEt DVC6200f Digital Valve Controller
RESOURCE BLOCK
FIELDVUE and Fisher are marks owned by Fisher Controls International LLC, a member of
the Emerson Process Management business division of Emerson Electric Co. Emerson,
Emerson Process Management, and the Emerson logo are trademarks and service marks
of Emerson Electric Co. All other marks are the property of their respective owners.
EFisher Controls International LLC 2010; All Rights Reserved
Top Level
Configure/Setup
Device Diagnostics
Device Variables
Options
Diagnostic Options
Function Block Options
Miscellaneous Options
Features Available
Device Variables
Instrument
Options
DD Information
Function Block Options
AO
DO
AI
DI
PID
IS
OS
MAI
Features Available
Reports
Fault State
Soft W Lock
Multi‐bit‐Alarm (Bit‐Alarm) Support
Miscellanous Options
Firmware Download
Travel Control Capable
Pressure Control Capable
Pressure Fallback Capable
Identification
Device ID
Electronics Serial Number
Factory Serial Number
Field Serial Number
Tag Description
Strategy
Manufacturer
Device Type
Version
Device Revision
Firmware Revision
Standby Firmware Revision
Hardware Rev
DD Revision
ITK Version
Device Diagnostics
Resource Block Error
Device State
Write Lock
Block Alarm
Maintenance
Identification
Device ID
Electronics Serial Number
Factory Serial Number
Field Serial Number
Tag Description
Strategy
Manufacturer
Device Type
Diagnostics Options
Resource Block Error
Other
Block Configuration Error
Simulate Active
Device Needs Maintenance Soon
Memory Failure
Lost Static Data
Lost NV Data
Device Needs Maintenance Now
Power Up
Out of Service
Write Lock
Write Alarm Alarm State
Write Lock
Block Alarm
Block Alarm Alarm State
Block Alarm Unacknowledged
Configure/Setup
Resource Block Mode
Write Lock
Comm Timeout
Options
Alarm Handling
Identification
Version
Alarm Handling
Alert Key
Confirm Time
Limit Notify
Maximum Notify
Block Alm Disabled
Block Alarm Auto Acknowledge
Disc Alm Disabled
Discrete Alarm Auto Acknowlege
Write Lock
Write Lock
Write Priority
Comm Timeout
Shed Remote Cascade
Shed Remote Out
Options
Diagnostic Options
Function Block Options
Miscellaneous Options
Features Available
Features Selected
Function Block Options
AO
DO
AI
DI
PID
IS
OS
MAI
Features Selected
Reports
Fault State
Soft W Lock
Multi‐bit‐Alarm (Bit‐Alarm) Support
Miscellaneous Options
Firmware Download
Travel Control Capable
Pressure Control Capable
Pressure Fallback Capable
Instrument
Identification
Version
Version
Device Revision
Firmware Revision
Standby Firmware Revision
Hardware Rev
DD Revision
ITK Version
Features Available
Reports
Fault State
Soft W Lock
Multi‐bit‐Alarm (Bit‐Alarm) Support
Maintenance
Restart Actions
Fault State
Set Fault State
Clear Fault State
Menu Tree applies to:
Device Revision DD RevisionFirmware Revision
2 2.0 2
Hardware Revision
8
Attach the Field Communicator to the TALK
Connections inside the DVC6200f Digital Valve
Controller Terminal Box
TALK
TALK
475 Field
Communicator
www.Fisher.com
For the telephone number of the Emerson Process
Management sales office nearest you, contact:
In North America
Fisher Controls International LLC
1 (641) 754–3011
In Latin America
Fisher Controls International LLC
1 (314) 746–9900
In Asia Pacific
Emerson Process Management
Asia Pacific Private Ltd.
(65) 6777–8211
In Europe
Emerson Process Management Ltd.
+44 1634 895800
For equipment service or support needs, contact your
local Emerson Process Management sales office.