Instruction Manual

Instruction Manual
D103557X012
Field Communicator Menu Trees
January 2015
91
Figure B-6. Manual Setup > Travel/Pressure Control (2-2-3) and Manual Setup > Tuning (2-2-4)
Manual Setup
1 Mode and Protection
2 Instrument
3 Travel/Pressure Control
4 Tuning
5 Valve and Actuator
6 Partial Stroke Test (PST)
7 Outputs
Travel/Pressure Control
1 End Point Pressure Control (EPPC)
2 Characterization
3 Dynamic Response
4 Travel Cutoffs
Travel Cutoffs
1 Hi Cutoff Point
3 Lo Cutoff Point
Dynamic Response
1 SP Rate Open
2 SP Rate Close
3 View/Edit Lag Time
Characterization
1 Input Characterization
2 Custom Characterization
End Point Pressure Control (EPPC)
1 EPPC Enab
2 Change EPPC Enab
3 EPPC Set Point
4 EPPC Saturation Time
2-2-3
2-2-3-1
2-2-3-2
2-2-3-3
2-2-3-4
NOTES:
1 SP RATE OPEN AND SP RATE CLOSE ARE NOT VISIBLE WHEN SHUTDOWN SWITCHS ARE ENABLED.
2 HI CUTOFF POINT AND LOW CUTOFF POINT ARE NOT VISIBLE WHEN SHUTDOWN SWITCHS ARE ENABLED.
1
2
Integral Settings
1 Integral Dead Zone
2 Integrator Limit
Tuning
1 Travel Tuning
2 Integral Settings
Travel Tuning
1 Travel Tuning Set
2 Proportional Gain
3 Velocity Gain
4 MLFB Gain
5 Integral Enable
6 Integral Gain
7 Performance Tuner
8 Stabilize/Optimize
2-2-4
2-2-4-2
2-2-4-1