Instruction Manual

DVC6000 SIS
iv
iv
78 910 11
A
B
C
D
E
F
G
H
I
12
Electronics Alerts
1 Drive Current Shutdown
2 Drive Signal Alert
3 Processor Impaired Alerts
Travel Tuning
1 Travel Tuning Set
2 Integral Enable
3 Integral Gain
4 Stabilize / Optimize
5 Performance Tuner
Integral Settings
1 Integral Dead Zone
2 Integral Limit
Pressure Tuning
1 Pressure Tuning Set
2 Integral Enable
3 Integral Gain
Travel/Pressure Cutoffs
1 Cutoff Hi
2 Cutoff Lo
3 Change Cutoffs
Drive Signal Alert
1 Drive Signal Alert Enable
2 Drive Signal
Processor Impaired Alerts
1 Offline/Failed Alert Enable
2 Low Power Write Fail Enable
3 Non-Critical NVM Alert Enable
4 Critical NVM Shutdown
5 Flash ROM Shutdown
6 No Free Time Shutdown
7 Reference Voltage Shutdown
Sensor Alerts
1 Travel Sensor Shutdown
2 Temp Sensor Shutdown
3 Pressure Sensor Shutdown
Environment Alerts
1 Auxiliary Terminal Alert
2 Supply Pressure Lo Alert
3 Loop Current Validation
Enable
Travel Limit Alerts
1 Travel Alert Hi Hi Enable
2 Travel Alert Lo Lo Enable
3 Travel Alert Hi Hi Point
4 Travel Alert Lo Lo Point
Travel Alerts
1 Travel
2 Set Point
3 Travel Alert DB
4 Travel Deviation Alert
5 Travel Limit Alerts
6 Travel Limit Hi/Lo Alerts
7 Travel Limit/Cutoff Alerts
Travel History Alerts
1 Cycle Counter
2 Cycle Count/Travel Accumulator Deadband
3 Travel Accumulator
Travel Limit Hi/Lo Alerts
1 Travel Alert Hi Enable
2 Travel Alert Lo Enable
3 Travel Alert Hi Point
4 Travel Alert Lo Point
Travel Limit/Cutoff Alerts
1 Travel Limit/Cutoff Hi Enable
2 Tvl Limit/Cutoff Lo Enable
3 Cutoff Hi
4 Cutoff Lo
5 Change Cutoffs
Integrator Saturation
1 Integrator Sat Hi Enable
2 Integrator Sat Lo Enable
3 Integral Limit
4 Integral Dead Zone
Travel Deviation Alert
1 Travel Deviation Alert Enable
2 Travel Deviation Alert Point
3 Travel Deviation Time
Travel Accumulator
1 Travel Accumulator Alert Enable
2 Travel Accumulator
3 Travel Accumulator Alert Point
Cycle Counter
1 Cycle Count Alert Enable
2 Cycle Counter
3 Cycle Count Alert Point
Instrument Time
1 Inst Time Invalid Enable
2 Instrument Date and Time
Calibrations and Diagnostics
1 Calibration in Progress Enable
2 Autocal in Progress Enable
3 Diagnostic in Progress Enable
4 Diagnostic Data Avail Enable
Operational
1 Pressure Control Active Enable
2 Multi-Drop Enable
1-2-2-1-1
1-2-2-2-1
1-2-3-1
1-2-3-1-2
End Point Pressure Control
1 End Pt Control Enab
2 PST Start Pt
3 EPPC Set Point
4 EPPC Saturation Time
1-2-2-2-2
SIS Alerts
1 PST Pressure Limit
2 Pressure Deviation Alert Enable
3 Pressure Deviation Alert Point
4 Pressure Deviation Time
Supply Pressure Lo Alert
1 Supply Pressure Lo Alert Enable
2 Supply
3 Supply Pressure Lo Alert Point
Auxiliary Terminal Alert
1 Auxiliary Terminal Alert Enable
2 Auxiliary Input
3 Auxiliary Terminal Action
Alert Record
1 Alert Record Has Entries Enable
2 Alert Record Full Enable
3 View Alert Records
4 Clear ALL Record
5 Alert Groups
Alert Groups
1 Failure Group Enable
2 Valve Group Enable
3 Miscellaneous Group Enable
Cycle Count/Travel
Accumulator Deadband
1 Deadband
1-2-3-6
1-2-3-2
1-2-3-3
1-2-3-5
1-2-3-7
1-2-2-1-2
1-2-2-1-3
1-2-3-5-1
1-2-3-75
1-2-4-2
1-2-4-3
1-2-4-4
1-2-4-1
1-2-3-5-3
1-2-3-5-2
1-2-3-1-3
1-2-3-4
1-2-3-3-1
1-2-3-3-2
1-2-3-4-4
1-2-3-4-5
1-2-3-4-6
1-2-3-4-7