Instruction Manual

DVC6000 SIS
i
i
Fast Key Sequence
Function/Variable
Fast-Key
Sequence
Coordinates
(1)
Function/Variable
Fast-Key
Sequence
Coordinates
(1)
A Minus B 3-5-3 4-G Drive Signal Alert Enable 1-2-3-1-2-1 9-D
Action on Failed Test 1-2-7-5 2-D Device Power Up 1-2-7-5 2-D
Actuator Style 1-2-6-4 2-E End Point Control Enable 1-2-2-2-2-1 9-C
Alert Conditions 2-1 2-F EPPC Saturation Time 1-2-2-2-2-4 9-C
Alert Record Full Enable 1-2-3-7-2 10-H EPPC Set Point 1-2-2-2-2-3 9-C
Alert Record Has Entries Alert
Enable
1-2-3-7-1 10-H Failure Group Enable 1-2-3-7-5-1 10-I
Analog Input 3-1 2-G Firmware Revision 3-7-6 2-H
Analog Input Calibration 1-3-2-3 4-E Flash ROM Shutdown 1-2-3-1-3-5 12-C
Analog Input Range Hi 1-2-5-3-1 6-H Hardware Revision 3-7-7 2-H
Analog Input Range Lo 1-2-5-3-2 6-H
HART Tag
1-2-5-1-1 6-F
Analog Input Units 1-2-5-2-3 6-G 3-7-1 2-H
Assembly Specification Sheet 1-2-6-7 2-E HART Universal Revision 3-7-9 2-H
Auto Test Interval 1-2-7-3 2-D Input Characterization 1-2-2-3 4-C
Auto Travel Calibration 1-3-1-1 4-D
Instrument Date and Time
1-2-4-1-2 8-G
Autocalibration in Progress Enable 1-2-4-2-2 8-H 1-2-5-8 4-G
Auxiliary Input
3-6-1 4-H Instrument Level 3-7-8 2-H
1-2-3-3-1-2 12-D Instrument Mode Hot Key-1 1-A
Auxiliary Terminal Alert Enable 1-2-3-3-1-1 12-D Instrument Mode 1-2-1-1 4-B
Auxiliary Terminal Action
1-2-3-3-1-3 12-D Instrument Serial Number 1-2-5-1-6 6-G
1-2-5-7 4-F Instrument Time Invalid Enable 1-2-4-1-1 8-G
Burst Command 1-2-1-4-3 5-B
Integral Dead Zone
1-2-4-4-4 8-I
Burst Enable 1-2-1-4-1 5-B 1-2-2-1-2-1 8-B
Calibration in Progress Enable 1-2-4-2-1 8-H
Integral Limit
1-2-4-4-3 8-I
Change Burst Command 1-2-1-4-4 5B 1-2-2-1-2-2 8-B
Change Burst Enable 1-2-1-4-2 5B Integrator Saturated Hi Enable 1-2-4-4-1 8-I
Clear ALL Records 1-2-3-7-4 10-H Integrator Saturated Lo Enable 1-2-4-4-2 8-I
Cmd 3 Configured Pressure 1-2-1-4-5 6B Last AutoCal Status 1-2-5-9-1 6-H
Control Mode
Hot Key-2 1-A Last Calibration Type 1-2-5-9-2 6-H
1-2-1-2 4-B
Low Power Write Fail Enable
(FW 9 and 10)
1-2-3-1-3-2 12-B
Critical NVM Shutdown 1-2-3-1-3-4 12-C Manual Travel Calibration 1-3-1-2 4-E
Custom Characterization Table 1-2-2-4 4-C
Manufacturer
3-7-3 2-H
Cycle Counter
1-2-3-5-1-2 12-G 1-2-6-1 2-D
3-6-5 4-H
Maximum Recorded Temperature
2-3-1 4-F
Cycle Count Alert Enable 1-2-3-5-1-1 12-G 3-6-3 4-H
Cycle Count Alert Point 1-2-3-5-1-3 12-G
Minimum Recorded Temperature
2-3-2 4F
Date 1-2-5-1-4 6-F 3-6-4 4-H
Dead Band (Cycle Count / Travel
Accum)
1-2-3-5-2-1 12-H Maximum Supply Pressure 1-2-5-6 4-F
Descriptor 1-2-5-1-3 6-F Message 1-2-5-1-2 6-F
Device Description Information 3-8 2-G Miscellaneous Group Enable 1-2-3-7-5-3 11-I
Device ID 3-7-2 2-H Model 3-7-4 2-H
Device Revision 3-7-5 2-H Multi-Drop Enable 1-2-4-3-2 8-H
Diagnostic Data Available Enable 1-2-4-2-4 8-H No Free Time Shutdown 1-2-3-1-3-6 12-C
Diagnostic in Progress Enable 1-2-4-2-3 8-H Non-Critical NVM Alert Enable 1-2-3-1-3-3 12-C
Drive Current Shutdown 1-2-3-1-1 8-D
Number of Power Ups
2-3-4 3-F
Drive Signal
3-4 2-G 3-6-9 4-I
1-2-3-1-2-2 9-D Offline/Failed Alert Enable 1-2-3-1-3-1 12-B
1. Coordinates are to help locate the menu item on the menu tree on the following pages.