Data Sheet
HF340 Filter
D102798X012
Product Bulletin
62.1:HF340
August 2012
2
Specifications
Mounting
Standard 35 mm DIN rail mounting with filtering
components.
Connections
Three 2-pin cage-clamp style connectors accept up to
12 AWG wire
Power Requirements
Input Current: 4-20 mA DC (nominal)
Input Voltage: At 20 milliamps DC, 2 volts above
input voltage required by the field instrument
(2 volt drop across filter at 20 milliamps DC)
Ambient Operating Temperature
-40 to 85_C (-40 to 185_F)
Ambient Relative Humidity
5 to 95%
Electromagnetic Compatibility
Meets EN 61326-1 (First Edition)
Immunity—Industrial locations per Table 2 of
the EN 61326-1 standard. Performance is
shown in table below 1.
Emissions—Class A
ISM equipment rating: Group 1, Class A
Dimensions
75 mm (3 inches) long by 12.5 mm (0.5 inches) wide
by 60 mm (2.4 inches) deep
Approximate Weight
0.1 kg (4 oz)
Option
HF341 communications tap: Standard 35 mm DIN rail
mounting without filtering components (straight
through with capacitor blocking on COMM
terminals). In case of an accidental short circuit across
the COMM terminal, a capacitor blocking circuit
prevents disruption of the 4 to 20 mA DC control
signal.
Table 1. EMC Summary Results; Immunity
Port Phenomenon Basic Standard Test Level Performance Criteria
Enclosure
Electrostatic discharge (ESD) IEC 61000-4-2
4 kV contact
8 kV air
A
EM field IEC 61000-4-3
80 to 100 MHz @ 10V/m with 1 kHz at 80%
1400 to 2000 MHz @ 3V/m with 1 kHz at 80%
2000 to 2700 MHz @ 1V/m with 1 kHz at 80%
A
Rated power frequency
magnetic field
IEC 61000-4-8 N/A
(1)
N/A
(1)
I/O signal/control
Burst IEC 61000-4-4 1 kV A
Surge IEC 61000-4-5 1 kV (line to ground only, each) A
Conducted RF IEC 61000-4-6 150 kHz to 80 MHz at 3 Vrms A
A = During testing, normal performance within the specification limits.
1. Not applicable; only applicable to magnetically sensitive equipment.