Instruction Manual

Instruction Manual
D103409X012
Installation
December 2013
23
Figure 2‐15. Air‐to‐Open Fisher GX Magnet Assembly
Alignment
W9218
ALIGNMENT TEMPLATE
INDEX MARK
RETAINING
SLOT
Figure 2‐16. Air‐to‐Close Fisher GX Magnet Assembly
Alignment
W9219
RETAINING
SLOT
INDEX MARK
ALIGNMENT TEMPLATE
5. Tighten the fasteners and remove the alignment template. Continue on with the appropriate step 6 below.
Note
Use a flat end hex key to tighten the mounting assembly fasteners to a torque of 2.37 Nm (21 inlbf) for 4 mm screws, and
5.08 Nm (45 inlbf) for 5 mm screws. While tightening the fasteners using the hex key should be sufficient, blue (medium) thread
locker may be used for additional security.
Air‐to‐Open GX Actuators
6. The pneumatic output port on the DVC6215 lines up with the integral GX actuator pneumatic port. See figure 2‐17.
7. Using a 5 mm hex wrench, attach the feedback unit to the GX actuator mounting pad on the side that has the open
pneumatic port. Be sure to place the O‐ring between the feedback units pneumatic output and the actuator
mounting pad. Pneumatic tubing between the feedback unit and the actuator is not required because the air
passages are internal to the actuator.
8. Connect the pneumatic tubing from the DVC6205 to the feedback units pneumatic port provided on the front of
the DVC6215 as shown in figure 2‐17.
9. Check for clearance between the magnet assembly and the DVC6215 feedback slot.
10. If not already installed, install a vent in the port on the upper diaphragm casing's air supply connection on the
actuator yoke leg.