Data Sheet
Sliding-Stem Live-Loaded Packing
Product Bulletin
59.1:061
July 2009
5
A6142
1/IL
ENVIRO-SEAL Graphite ULF and
HIGH-SEAL Graphite ULF
Figure 3. Applications Guidelines for 100 ppm Service
Temperature, F
Pressure, PSI
Temperature, C
Pressure, Bar
240
184
129 73 18 38 94 149
205 260 316
371 427 483
538
594
649
400
300
200 100 0 100 200 300 400 500 600
700 800 900
1000 1100
1200
4500
4000
3500
3000
2500
2000
1500
1000
500
310
276
241
207
172
138
103
69
34
0
HIGH-SEAL
GRAPHITE
ENVIRO-SEAL PTFE AND
ENVIRO-SEAL DUPLEX
HIGH-SEAL
GRAPHITE ULF
ENVIRO-SEAL
GRAPHITE ULF
0
Figure 4. Applications Guidelines for Nonenvironmental Service
Ordering Information
When ordering, specify:
For Existing Valves
1. Process fluid
2. Process fluid temperature
3. Maximum valve inlet pressures
4. Maximum valve pressure drops
5. Valve design (ED, YD, etc.), size, and pressure
rating
6. Valve stem diameter and bonnet type (plain,
extension, or bellows)
7. Refer to the specifications. Review the information
under each specification. Write down your choice
whenever a selection is to be made.
For New Valves
1. Refer to the valve bulletin for ordering information.
2. Also refer to the specifications. Review the
information under each specification and in the
referenced tables; write down your choice whenever
there is a selection to be made.