Instruction Manual

Instruction Manual
D100397X012
ES Valve
October 2014
5
instructions. Figure 9 shows a typical HIGH-SEAL Packing system. Figures 10, 11, and 12 show typical ENVIRO-SEAL packing
systems.
If the valve has an ENVIRO-SEAL bellows seal bonnet installed, refer to this manual. See the ENVIRO-SEAL Bellows Seal and Bonnet
section for information on the bellows seal bonnet.
Figure 2. Optional Lubricator and Lubricator/Isolating Valve
LUBRICATOR LUBRICATOR/ISOLATING VALVE
10A9421-A
AJ5428-D
A0832-2
Table 3. Body-to-Bonnet Bolt Torque Guidelines
VALVE SIZE, NPS BOLT TORQUES
(1, 4)
ES EAS
SA193-B7, SA193-B8M
(3)
SA193-B8M
(2)
NSm LbfSft NSm LbfSft
1-1/4 or less 1 129 95 64 47
1-1/2, 1-1/2 x 1, 2, or 2 x 1 2or2x1 96 71 45 33
2-1/2 or 2-1/2 x 1-1/2 3or3x1-1/2 129 95 64 47
3, 3 x 2, or 3 x 2-1/2 4or4x2 169 125 88 65
4, 4 x 2-1/2, or 4 x 3 6or6x2-1/2 271 200 156 115
6 --- 549 405 366 270
8 --- 746 550 529 390
1. Determined from laboratory tests.
2. SA193-B8M annealed.
3. SA193-B8M strain hardened.
4. For other materials, contact your Emerson Process Management sales office for torques.
Packing Lubrication
Note
ENVIRO-SEAL or HIGH-SEAL packing does not require lubrication.
WARNING
To avoid personal injury or property damage resulting from fire or explosion, do not lubricate packing used in oxygen
service or in processes with temperatures over 260_C (500_F).
If a lubricator or lubricator/isolating valve (figure 2) is provided for PTFE/composition or other packings that require
lubrication, it will be installed in place of the pipe plug (key 14, figure 8). Use a good quality silicon-base lubricant.
Packingusedinoxygenserviceorinprocesses with temperatures over 260_C(500_F) should not be lubricated. To