Table 11. For ASME Standard CL2500 Valves
(1)
SERVICE
TEMP (_F)
WORKING PRESSURE (PSIG)
LCC LF2 WCC WC6 WC9
C12A
(2)
CF8
(2,3)
or
304
(2,3)
CF8M
(2,3)
or 316
(2,3)
CF3M 316L CG8M
317
(2,3)
CF8C
(2,3)
347
CK3MCuN
CD3MN
CD3MWCuN
-20 to 100
200
300
400
500
6250
6250
6070
5865
5540
6170
5655
5450
5280
5025
6250
6250
6070
5865
5540
6250
6250
6015
5775
5540
6250
6250
6070
5880
5540
6250
6250
6070
5880
5540
6000
5000
4480
4140
3880
6000
5160
4660
4280
3980
6000
5160
4660
4280
3980
5000
4260
3800
3500
3280
6000
5160
4660
4280
3980
6000
5160
4660
4280
3980
6000
5520
5140
4800
4520
6000
5520
5140
4800
4520
6250
6200
5560
5120
4840
600
650
700
750
800
5040
4905
---
---
---
4730
4575
4425
4230
3430
5040
4905
4630
4230
3430
5040
4905
4730
4430
4230
5040
4905
4730
4430
4230
5040
4905
4730
4430
4230
3680
3600
3520
3440
3380
3760
3680
3620
3560
3520
3760
3680
3620
3560
3520
3100
3040
3000
2940
2880
3760
3680
3620
3560
3520
3760
3680
3620
3560
3520
4300
4220
4140
4100
4060
4300
4220
4140
4100
4060
4640
4560
4520
4430
---
850
900
950
1000
1050
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
4060
3745
2655
1800
1200
4060
3745
3220
2230
1455
4060
3745
3220
3030
3000
3300
3240
3180
2950
2715
3480
3460
3220
3030
3000
3480
---
---
---
---
2820
---
---
---
---
3480
3460
3220
3030
---
3480
3460
3220
3030
3000
4040
3745
3220
3030
3000
4040
3745
3220
3030
---
---
---
---
---
---
1100
1150
1200
1250
1300
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
800
---
---
---
---
915
---
---
---
---
2515
1855
1200
---
---
2145
1715
1370
1115
945
2545
1970
1545
1230
970
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
2545
1970
1545
1230
970
2600
1745
1255
945
630
---
---
---
---
---
---
---
---
---
---
1350
1400
1450
1500
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
770
630
485
345
800
630
485
345
---
---
---
---
---
---
---
---
---
---
---
---
800
630
485
345
430
345
255
230
---
---
---
---
---
---
---
---
1. Table information is extracted from the Valve–Flanged, Threaded, and Welding End, ASME Standard B16.34-2013. These tables must be used in accordance with the ASME s tandard. The
user is advised that a valve used under the jurisdiction of the ASME Boiler and Pressure Vessel Code, ASME Code for Pressure Piping, or governmental regulations is subject to any limitation of
that code or regulation. This includes any maximum temperature limitation for a material or rule governing the use of a material at a low temperature.” Information copied with permission of
the publisher; The American Society of Mechanical Engineers, 345 East 47th Street, New York, New York, 10017.
2. Flanged end ratings terminate at 1000_F.
3. At temperatures over 1000_F, use material only when carbo n content is 0.04% or higher.