Brochure

Fisher
®
easy-e
Sliding-Stem Control Valves | 7
Noise Abatement
Control valve noise is a concern for plant operators and maintenance personnel because it can affect plant
availability and protability. High noise levels can cause health concerns for plant personnel and cause
equipment damage, vibration, and control issues. There is no single technology or treatment that can
solve all noise issues cost effectively or efciency. For that reason, a wide range of Fisher noise-attenuating
trims are available for vapor, gas, or steam applications.
Whisper Trim
I
Provides an economical, yet
proven, means of control valve
noise reduction in a slotted-
cage guided trim design. Noise
can be effectively reduced by
up to 18 dBA through specially
designed ow passages
that break up turbulent
streams and ensure exit jet
independence.
Whisper Trim
III
Offers a highly exible means
of noise reduction in a drilled-
hole, cage-guided trim design.
Up to 30 dBA of attenuation
is possible through the use of
specially designed passages
that shift frequencies to
higher, less problematic
levels and ensure exit jet
independence.
WhisperFlo
Trim
This multi-path, multi-stage
trim reduces noise by as much
as 40 dBA across ve areas.
The cage in this trim design
is composed of specially
designed, laser cut ow discs
that deliver a breakthrough
combination of high capacity
and noise abatement
performance.