Ordering Information
When ordering, specify:
1. Type of measurement
J Level or J Interface
2. Process fluid type
J Water, J Saline water, J Saturated water,
J Saturated steam,J Crude oil, J Refined
product,
J Gas well condensate, or J Customer
specified fluid
Note
If Interface indicate both upper and lower fluid types.
3. Process operating conditions
Temperature ______________________________
Fluid density or SG __________________________
Note
If Interface indicate fluid density or SG for both upper and
lower fluids.
4. Tag number, as required _____________________
Figure 1. Guidelines for Use of Optional Heat
Insulator Assembly
HEAT INSULATOR
REQUIRED
70
0 20 40 60 80 100 120 140 160
010 20
-20 -10
30 40 50 60
400
300
200
100
0
0
400
800
-325
AMBIENT TEMPERATURE (_C)
STANDARD TRANSMITTER
AMBIENT TEMPERATURE (_F)
HEAT INSULATOR
REQUIRED
TOO
HOT
425
80
-100
-200
176
-20-40
-40 -30
TOO
COLD
1
NO HEAT INSULATOR NECESSARY
PROCESS TEMPERATURE (_F)
PROCESS TEMPERATURE (_C)
Notes:
1 For process temperatures below -29_C (-20_F) and above 204_C (400_F)
sensor materials must be appropriate for the process (refer to bulletin
34.2:2500)
2. If ambient dew point is above process temperature, ice formation might
cause instrument malfunction and reduce insulator effectiveness.
39A4070‐B
A5494‐1
Optional Heat Insulator
If the DLC3020f and a 249 sensor are ordered as an
assembly, and a heat insulator is required for the
application, order the heat insulator as a 249 sensor
option. If the DLC3020f is ordered separately, the heat
insulator is available as a kit. Figure 1 contains
guidelines for use of the optional heat insulator.
Emerson Process Management
Marshalltown, Iowa 50158 USA
Sorocaba, 18087 Brazil
Chatham, Kent ME4 4QZ UK
Dubai, United Arab Emirates
Singapore 128461 Singapore
www.Fisher.com
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not
to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are
governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such
products at any time without notice.
E 2010, 2014 Fisher Controls International LLC. All rights reserved.
Fisher and FIELDVUE are marks owned by one of the companies in the Emerson Process Management business unit of Emerson Electric Co. Emerson Process
Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective
owners.
Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance
of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user.