Data Sheet

www.Fisher.com
Fisher
r
FIELDVUE
t
DLC3020f Digital Level
Controller for F
OUNDATION
t
fieldbus
The FIELDVUE DLC3020f digital level controller is a
fieldbus communicating instrument used to measure
liquid level or the level of interface between two
liquids using displacement sensor technology.
In addition to the normal function of reporting process
level PV, the DLC3020f, using F
OUNDATION fieldbus
protocol, gives easy access to information critical to
process operation and will readily integrate into a new
or existing control system. AMS Suite: Intelligent
Device Manager or the 475 Field Communicator can
be used to configure, calibrate, or test the digital level
controller.
The DLC3020f is also designed to directly replace
pneumatic, analog, or HARTr transmitters/
controllers. It can be mounted on a wide variety of 249
cageless and caged level sensors as well as on other
displacer type level sensors through the use of
mounting adaptors.
Features
nEase of Use The DLC3020f, a fieldbus level or
interface transmitter, features the latest in user
interface technology. In addition to reporting the
PV, the DLC3020f can act as a PID controller or level
switch.
nGuided Setup and Calibration Leads you through
instrument setup, process fluid selection, and
calibration in an easy‐to‐use format.
W9954-1_DLC3020f
nDynamic Temperature Compensation Integration
of process fluid temperature, when needed, enables
density compensation to maintain PV accuracy.
nSimple Process Fluid Configuration The capability to
easily select/define process fluids allows for fluid
changes without requiring re-calibration.
nCalibration/Setup Logs Saved in Instrument
Logs, including calibration, instrument setup, and
process fluid data, can be saved for future reference
or re‐use in batch or continuous applications. The
instrument stores up to 30 logs.
nPerformance/Reliability State‐of‐the‐art Emerson
advanced electronics provide increased
performance and reliability.
DLC3020f Digital Level Controller
D103433X012
Product Bulletin
11.2:DLC3020f
November 2014