Instruction Manual

Function/Variable Fast‐Key Sequence
Active Alerts 3-1
Alarm Jumper 1-7-3-1-1
Analog Output
1-5
3-2-3
Burst Mode 2-4-1
Burst Options 2-4-2
Calibration, Guided 2-5-1-1
Calibration, Min/Max 2-5-1-2-1
Calibration, Partial, Capture Zero 2-5-1-3-1
Calibration, Partial, Trim Gain 2-5-1-3-2
Calibration, Partial, Trim Zero 2-5-1-3-3
Calibration, Temperature 2-5-2-1
Calibration, Two Point 2-5-1-2-2
Calibration, Weight 2-5-1-2-3
Change Process Temperature
2-2-3-2
(1)
2-2-3-2-2
(2)(3)
Change Primary Variable
Hot Key-3
2-2-2-1-2
Change Torque Rate 2-2-1-3-2
Comm Status 1-2
Date
1-7-1-8
2-2-4-2
DD Information 1-7-2-5
Decimal Places 2-2-5-4
Descriptor
1-7-1-9
2-2-4-3
Device ID 1-7-1-4
Device Status 1-1
Display Alert/Saturation Level 1-7-3-1-2
Display Mode 2-2-5-2
Distributor 1-7-1-2
Enter Constant Density
Hot-Key-4
2-2-3-1-3
(2)(5)
2-2-3-1-4
(2)(6)
Field Device Revision 1-7-2-2
Final Assembly Number
1-7-1-7
2-2-4-8-3
Firmware Revision 1-7-2-3
Guided Setup 2-1
Hardware Revision 1-7-2-4
Function/Variable Fast‐Key Sequence
HART Tag
1-7-1-1
2-2-4-1
HART Universal Revision 1-7-2-1
Instrument Mounting 2-2-1-4
Instrument Serial Number
1-7-1-5
2-2-4-8-1
Instrument Temperature 3-2-4
Instrument Temperature (Alert Setup) 2-3-2-1
LCD Configuration 2-2-5-1
LCD Test 3-3-1-1
(4)
Level Offset 2-2-2-1-4
Loop Test
3-3-1-1
3-3-1-2
(4)
Lower Density Table
(3)
2-2-3-1-2-1
(3)(5)
2-2-3-1-3-2
(3)(6)
Lower Fluid Density
2-2-3-1-1
(3)(5)
2-2-3-1-2
(3)(6)
3-2-7
(5)
3-2-8
(6)
Lower Range Value
2-2-2-3-2
2-3-1-4
Lower Sensor Limit 2-2-2-2-2
Measure Density 2-2-3-1-4
(3)(5)
Message 2-2-4-4
Minimum Sensor Span 2-2-2-2-3
Model (Device) 1-7-1-3
Number of Request Preambles 2-2-4-7
Percent Range
1-4-2
3-2-2-2
(3)
Physical Signalling Code 2-2-4-6
Polling Address 2-2-4-5
Primary Variable Hi (Alert Setup) 2-3-1-1
Primary Variable Lo (Alert Setup) 2-3-1-2
Process Temperature
1-6-2
2-2-3-2-3
(2)(3)
2-2-3-3
(1)
3-2-5-2
(3)
Process Temperature (Alert Setup) 2-3-2-2
Process Temperature Source
1-6-1
2-2-3-1
(1)
Function/Variable Fast‐Key Sequence
Process Temperature Source 2-2-3-2-1
(2)(3)
PV Alerts Threshold Deadband 2-3-1-5
PV Damping 2-2-2-4
PV is
1-3
2-2-2-1-1
PV Units 2-2-2-1-3
PV Value
1-4-1
3-2-2-1
(3)
Reset Device 3-3-2-2
Restore Factory Defaults 3-3-2-1
RTD Wire Resistance
2-2-3-2-4
(2)(3)
2-2-3-4
(1)
Scaled D/A Trim 2-5-2-2-1
Sensor Damping 2-2-1-5
Sensor Dimensions (Displacer Units) 2-2-1-2
Sensor Serial Number
1-7-1-6
2-2-4-8-2
Sensor Units 2-2-1-1
Set Level Offset 2-2-2-1-5
Torque Rate
2-2-1-3-1
3-2-6
Torque Tube Compensation Selection 2-2-1-3-4
Torque Tube Compensation Table 2-2-1-3-5
Torque Tube Material 2-2-1-3-3
Upper Density Table 2-2-3-1-3-1
(3)(6)
Upper Fluid Density
2-2-3-1-1
(3)(6)
3-2-7
(6)
Upper Range Value
2-2-2-3-1
2-3-1-3
Upper Sensor Limit 2-2-2-2-1
View/Change AO Action 2-2-2-3-3
Write Lock
Hot Key-1
1-7-3-2-1
Write Lock Setup
Hot Key-2
1-7-3-2-2
1. If PV is Density
2. If PV is Level or Interface
3. Not included in menu tree
4. LCD Configuration is installed
5. If PV is Level
6. If PV is Interface
Alert Setup
1 Primary Variable
2 Temperature
2‐3-1
Primary Variable
1 Primary Variable Hi
2 Primary Variable Lo
3 Upper Range Value
4 Lower Range Value
5 PV Alerts Threshold
5 Deadband
Hi Alert
1 PV Hi Alert Enable
2 PV Hi Alert Threshold
3 PV Hi Alert Threshold
HiHi Alert
1 PV HiHi Alert Enable
2 PV HiHi Alert Threshold
3 PV HiHi Alert Threshold
Primary Variable Hi
1 Hi Alert
2 HiHi Alert
Lo Alert
1 PV Lo Alert Enable
2 PV Lo Alert Threshold
3 PV Lo Alert Threshold
LoLo Alert
1 PV LoLo Alert Enable
2 PV LoLo Alert Threshold
3 PV LoLo Alert Threshold
Primary Variable Lo
1 Lo Alert
2 LoLo Alert
Temperature
1 Instrument Temperature
2 Process Temperature
Instrument Temperature
1 Hi Alert
2 Lo Alert
3 Inst Temp
4 Inst Temp Offset
Process Temperature
1 Hi Alert
2 Lo Alert
3 Proc Temp
4 Proc Temp Offset
Hi Alert
1 Inst Temp Hi Alert Enable
2 Inst Temp Hi Alert Threshold
Lo Alert
1 Inst Temp Lo Alert Enable
2 Inst Temp Lo Alert Threshold
Hi Alert
1 Proc Temp Hi Alert Enable
2 Proc Temp Hi Alert Threshold
Lo Alert
1 Proc Temp Lo Alert Enable
2 Proc Temp Lo Alert Threshold
2‐3-1-1
2‐3-1-1-2
2‐3-1-1-1
2‐3-1-2
2‐3-1-2-1
2‐3-1-2-2
2‐3-2
2‐3-2-1
2‐3-2-1-2
2‐3-2-1-1
2‐3-2-2
2‐3-2-2-2
2‐3-2-2-1
2‐3
Configure
1 Guided Setup
2 Manual Setup
3 Alert Setup
4 Communications
5 Calibration
2
Alert Setup
Italics text indicates Method