User Guide

Rotary Valve Selection Guide
Product Flier
PF51.3:010
October 2010
3
Fisher Vee-Ball Valves
V150 and V300 VALVES
W5787/IL
V200 VALVE
W74351/IL
W8509/IL
V150S VALVE
Figure 3. Fisher Vee-Ball Valves
V150 AND V300 V200 V150S
Applications
Excellent for fibrous slurries as well as liquids,
gas, and steam. Shearing V-notch ball for
smooth, non-clogging action.
Excellent for fibrous slurries as well as liquids,
gas, and steam. Shearing V-notch ball for
smooth, non-clogging action.
Highly wear-resistant trim materials and an
unrestricted flow path make this design ideal for
controlling the most abrasive of slurries.
Sizes
V150: DN 25 - 500 or NPS 1 - 24 x 20
V300: DN 25 - 500 or NPS 1 - 20
NPS 1, 1-1/2, 2, 3, 4, 6, 8, 10
NPS 3, 4, 6, 8, 10, 12
Ratings
V150: PN 10/16 or CL150
V300: PN 25/40 or CL300
CL150, CL300, or CL600 depending on size. CL150
End Connections
Raised-face (RF) flanged
Flangeless
Raised-face (RF) flanged
Valve Body Materials
EN: 1.0619 steel, 1.4409 stainless steel, M35-1,
or CW2M
ASME: SA216 WCC steel, SA351 CF3M, CG8M
stainless steel, M35-1, or CW2M
EN: 1.0619 steel, 1.4409 stainless steel, M35-1,
or CW2M
ASME: SA216 WCC steel, SA351 CF3M,
CG8M stainless steel, M35-1, or CW2M
SA216 WCC steel body liner: (high-chrome iron
SA532 Class III Type A)
Ball Material
SA351 CF3M, or CG8M stainless steel, CW2M SA351 CF3M or CG8M stainless steel, CW2M
High-chrome iron SA532 Class III Type A (PSZ
ceramic ball is optional)
Seal Types (Material)
TCM Plus, metal (S31600), HD (heavy duty)
metal, or flow ring
TCM Plus, metal (S31600), HD (heavy duty)
metal, or flow ring
Flow ring construction
Flow Characteristics and Maximum Flow Coefficients
Modified equal percentage
Maximum Cv from 3.64 to 10,300
Modified equal percentage
Maximum Cv from 8.4 to 3000
Modified equal percentage
Maximum Cv from 170 to 2850
Rangeability
300 to 1 300 to 1
Shutoff Class
Composition Seal: Class VI
Metal Seal: Class IV
Flow Ring Construction: 5% of wideopen
capacity
Composition Seal: Class VI
Metal Seal: Class IV
Flow Ring Construction: 5% of wideopen
capacity
Class I
Available Actuators (refer to page 12)
Fisher 2052, 1051, 1052, 1061, and FieldQ