Instruction Manual
Instruction Manual
D103298X012
Control-Disk Valve
May 2011
8
WARNING
Avoid personal injury and property damage from sudden release of process pressure or bursting of parts. Before
performing any maintenance operations:
D Do not remove the actuator from the valve while the valve is still pressurized.
D Always wear protective gloves, clothing, and eyewear when performing any maintenance operations.
D Disconnect any operating lines providing air pressure, electric power, or a control signal to the actuator. Be sure the
actuator cannot suddenly open or close the valve.
D Use bypass valves or completely shut off the process to isolate the valve from process pressure. Relieve process pressure
on both sides of the valve. Drain the process media from both sides of the valve.
D Vent the power actuator loading pressure and relieve any spring precompression.
D Use lock‐out procedures to be sure the above measures stay in effect while you work on the equipment.
D The valve packing box may contain process fluids that are pressurized, even when the valve has been removed from the
pipeline. Process fluids may spray out when removing the packing hardware or packing rings, or when loosening the
packing box pipe plug.
D Check with your process or safety engineer for any additional measures that must be taken to protect against process
media.
Figure 4. Optional Shaft‐to‐Valve Body Bonding Strap Assembly
Packing Maintenance
Refer to figure 5 for available packing configurations. All maintenance operations in this section may be performed
with the valve in the line. Packing may be PTFE V‐ring or graphite.
An ENVIRO‐SEAL packing system is also available with the Control‐Disk valve. To install the ENVIRO‐SEAL packing
system in an existing valve, follow the instructions in the instruction manual included with the packing system
(D101643X012). To remove packing parts in a valve with the ENVIRO‐SEAL packing system, follow the procedures for
valves with the ENVIRO‐SEAL packing system in this section. Install the replacement packing following the instructions
in the packing system instruction manual (D101643X012).
Stopping Leakage
For valves with PTFE or graphite packing: