Data Sheet
Control-Disk NPS 14-24 Valve
D103471X012
Product Bulletin
51.3:Control-Disk NPS 14-24
October 2013
6
Table 3. Valve/Actuator Combinations
TEMPERATURE RANGE
SELECTION GUIDELINES
1052, 1061 or 2052
From -46 to 343_C
(-50 to 650_F)
Valve (select appropriate trim) and standard actuator
From 343 to 426_C
(650 to 800_F)
Mounting positions 1 and 3
Valve (select appropriate trim) and standard actuator
From 426 to 538_C
(800 to 1000_F)
(1)
Mounting positions 1 and 3
Valve (select appropriate trim) and standard actuator
1. Consult your Emerson Process Mana gement sales office.
Figure 4. Mounting Styles and Positions
STYLE A
STYLE C
STYLE B
STYLE D
POSITION 1
STANDARD
NORMAL
FLOW
POSITION 1
STANDARD
2
3
4
2
3
4
POSITION 1
STANDARD
POSITION 1
STANDARD
4
4
33
2
2
NORMAL
FLOW
GE37285