Table 5. Hex Head Screw, Stud Bolt and Cap Screw Data
(1)
VALVE
SIZE, NPS
NO. OF CAP SCREWS NO. OF STUD BOLTS
SIZE‐DIA. INCH &
THREAD
LENGTH OF CAP
SCREWS, INCH
LENGTH OF STUD BOLTS,
INCH
CL150 CL300 CL150 CL300 CL150 CL300 CL150 CL300 CL150 CL300
Single-Flange Style
(2)
14 24 40 ‐ ‐ ‐ ‐ ‐ ‐ 1‐8 1‐1/8‐8 2.75 3.5 ‐ ‐ ‐ ‐ ‐ ‐
16 32 40 ‐ ‐ ‐ ‐ ‐ ‐ 1‐8 1‐1/4‐8 3 3.75 ‐ ‐ ‐ ‐ ‐ ‐
18 32 48 ‐ ‐ ‐ ‐ ‐ ‐ 1‐1/8‐8 1‐1/4‐8 3.25 4 ‐ ‐ ‐ ‐ ‐ ‐
20 40 48 ‐ ‐ ‐ ‐ ‐ ‐ 1‐1/8‐8 1‐1/4‐8 3.5 4 ‐ ‐ ‐ ‐ ‐ ‐
24 40 48 ‐ ‐ ‐ ‐ ‐ ‐ 1‐1/4‐8 1-1/2‐8 3.5 4.5 ‐ ‐ ‐ ‐ ‐ ‐
30 8 8 24 24 1‐1/4‐8 1‐3/4‐8 4.5 5.75 15.5 21.5
36 8 8 28 28 1‐1/2‐8 2‐8 5.25 6.5 18 24.25
Wafer-Style
14 ‐ ‐ ‐ 8 12 16 1‐8 1‐1/8‐8 ‐ ‐ ‐ 3.5 9.5 12
16 ‐ ‐ ‐ 8 16 16 1‐8 1‐1/8‐8 ‐ ‐ ‐ 3.75 10 13.5
18 ‐ ‐ ‐ 8 16 16 1‐1/8‐8 1‐1/4‐8 ‐ ‐ ‐ 4 11 13.75
20 ‐ ‐ ‐ 8 20 20 1‐1/8‐8 1‐1/4‐8 ‐ ‐ ‐ 4 12 14.5
24 ‐ ‐ ‐ 8 20 20 1‐1/4‐8 1‐1/2‐8 ‐ ‐ ‐ 4.5 14 16.5
30 56 56 ‐ ‐ ‐ ‐ ‐ ‐ 1‐1/4‐8 1‐3/4‐8 4.5 5.75 ‐ ‐ ‐ ‐ ‐ ‐
36 64 64 ‐ ‐ ‐ ‐ ‐ ‐ 1‐1/2‐8 2‐8 5.25 6.5 ‐ ‐ ‐ ‐ ‐ ‐
1. Thread engagement in accordance with ASME B31.3 “Chemical Plant and Petroleum Refinery Piping”.
2. Bolting lengths are based on installation of valve between standard raised face flanges and utilizing flange gaskets with a final compression thickness of 0.125 inch. When gaskets used have
a final compression thickness of less than 0.125 inch, reduce bolting lengths shown by 0.25 inch.
Figure 4. Installation of Wafer‐Style Valves
A5557
1. See figure 4 for recommended valve orientation.
DFor Wafer‐Style Valves: Install the lower flange bolts first to form a cradle for the valve (see figure 5). See table 5 for
flange bolt specifications.
DFor Single‐Flange Valves: Position the valve between the flanges. Be sure to leave enough room for the flange
gaskets. Install the lower flange bolts.
2. For all Valves: Select the appropriate gaskets for the application. Flat sheet, spiral wound, or other gasket types,
made to the ASME B16.5 standard or user's standard, can be used on Control-Disk valves depending on the service