Instruction Manual
Instruction Manual
D103545X012
Control-Disk NPS 14-36
April 2011
5
If the Control-Disk valve is equipped with a fail‐open actuator, cycle the valve into the fully closed position. Ensure the valve
cannot open during installation by using a manual actuator, a constant supply pressure to the pneumatic actuator, or other
steps as necessary.
Table 3. Valve Body Data, CL150
VALVE SIZE, NPS
SHAFT DIAMETER AT
ACTUATOR YOKE
FACE‐TO‐FACE
DIMENSION
(1)
MINIMUM I.D.
(2)
APPROXIMATE WEIGHT, KILOGRAMS
mm Wafer Single‐Flange
14 31.8 92.1 331.2 79.8 103
16 31.8 102 375.2 106 150
18 39.7 114 418.8 152 191
20 44.5 127 464.1 191 248
24 57.2 154 580.9 286 381
30
(3)
159 723.9 625 824
36
(3)
178 876.3 934 1250
VALVE SIZE, NPS
SHAFT DIAMETER AT
ACTUATOR YOKE
FACE‐TO‐FACE
DIMENSION
(1)
MINIMUM I.D.
(2)
APPROXIMATE WEIGHT, POUNDS
Inches Wafer Single‐Flange
14 1.25 3.63 13.04 176 227
16 1.25 4.00 14.77 233 330
18 1.56 4.50 16.49 336 422
20 1.75 5.00 18.27 421 546
24 2.25 6.06 22.87 630 840
30
(3)
6.25 28.5 1380 1820
36
(3)
7.00 34.5 2060 2750
1. NPS 14 to 24 face‐to‐face dimensions are in compliance with MSS SP68 and API 609 specifications.
2. Minimum I.D. is the minimum pipe or flange I.D. required for disk swing clearance.
3. Contact your Emerson Process Management sales office for information.
Table 4. Valve Body Data, CL300
VALVE SIZE, NPS
SHAFT DIAMETER AT
ACTUATOR YOKE
FACE‐TO‐FACE
DIMENSION
(1)
MINIMUM I.D
.(2)
APPROXIMATE WEIGHT,
KILOGRAMS
mm Wafer Single‐Flange
14 44.5 118 304.3 143 249
16 44.5 133 346.2 203 314
18 57.2 149 389.4 253 427
20 76.2 156 442.0 388 568
24 88.9 181 523.2 501 853
30
(3)
241 670.6 1070 1520
36
(3)
273 828.0 1470 2150
VALVE SIZE, NPS
SHAFT DIAMETER AT
ACTUATOR YOKE
FACE‐TO‐FACE
DIMENSION
(1)
MINIMUM I.D
.(2)
APPROXIMATE WEIGHT,
POUNDS
Inches Wafer Single‐Flange
14 1.75 4.63 11.98 315 549
16 1.75 5.25 13.63 447 693
18 2.25 5.88 15.32 558 941
20 3.00 6.13 17.40 855 1250
24 3.50 7.13 20.59 1110 1880
30
(3)
9.50 26.4 2360 3360
36
(3)
10.8 32.6 3240 4730
1. Face‐to‐face dimensions are in compliance with MSS SP68 and API 609 specifications.
2. Minimum I.D. is the minimum pipe or flange I.D. required for disk swing clearance.