Instruction Manual

Instruction Manual
D103545X012
Control-Disk NPS 14-36
April 2011
2
Table 1. Specifications
Valve Size and End Connection Styles
J NPS 14, J 16, J 18, J 20, J 24, J 30, or J 36
valves, in J wafer‐style (flangeless) or
J single‐flange (lugged) with raised‐face flanges,
CL150 or CL300
Maximum Pressure Drop
(1)
Consistent with CL150 and CL300
pressure/temperature ratings per ASME B16.34.
Contact your Emerson Process Management sales
office for additional information
Shutoff Classification Per ANSI/FCI 70‐2 and IEC
60534‐4
Standard Soft Seal: Bidirectional shutoff Class VI
(bubble‐tight)
NOVEX Seal: Unidirectional shutoff Class V (reverse
flow direction only)
Phoenix III Seal: Bidirectional shutoff Class VI
(bubble‐tight)
Phoenix III Seal for Fire‐Tested Applications:
Unidirectional shutoff Class VI (reverse flow direction
only) (bubble‐tight). Fire Tested per API 607 Rev. 4.
For cryogenic seal applications, consult your Emerson
Process Management sales office
Available Seal Configurations
Standard Constructions
See figure 2 and table 2
Standard Construction Materials
See table 2
Flow Characteristic
Equal percentage
Flow Coefficients
Contact your Emerson Process Management sales
office
Flow Coefficient Ratio
(2)
100 to 1
Noise Levels
See Catalog 12 for sound/pressure level prediction
Valve In‐Line Position
Shaft horizontal. See figure 4
Valve/Actuator Action
With diaphragm or piston rotary actuator,
field‐reversible between:
J push‐down‐to‐close (extending actuator rod
closes valve) and
J push‐down‐to‐open (extending actuator rod
opens valve)
Valve Body Classification
NPS 14 to 24: Face‐to‐face dimensions are in
compliance with MSS SP68 and API 609 standards.
Valve bodies are designed for installation between
ASME B16.5 CL150 and CL300 raised‐face flanges
NPS 30 to 36: Valve bodies are designed for
installation between ASME B16.47 CL150 and CL300
raised‐face flanges
Disk Rotation
Clockwise to close (when viewing from the drive shaft
end) through 90 degrees rotation
Shaft Diameter and Approximate Weight
See tables 3 and 4
ENVIRO‐SEAL™ Packing
This optional packing system provides improved
sealing, guiding, and transmission of loading force to
control liquid and gas emissions. Contact your
Emerson Process Management sales office for
availability of ENVIRO‐SEAL packing
1. The pressure/temperature limits in this manual, and any applicable code or standard limitation should not be exceeded.
2. Ratio of maximum flow coefficient to minimum usable flow coefficient may also be called rangeability.
Description
The valve is available in either a flangeless wafer body or a single‐flange (lugged) body design, with a variety of seals
and internal components. The pressure‐assisted seal provides tight shutoff. The upper (splined) shaft combines with a
variety of pneumatic piston or spring‐and‐diaphragm actuators. Maximum inlet pressure/temperature ratings are
consistent with CL150 and CL300.