Data Sheet

24000F Valve
D103330X012
Product Bulletin
52.1:24WF
March 2013
10
Table17.AllowablePressureDrops(bar)
PORT
DIA.
(mm)
PLUG
TRAVEL
(mm)
ACT
TYPE
AIR-TO-OPEN ACTION AIR-TO-CLOSE ACTION
BENCH
RANGE
(barg)
0.2-1.0 barg SIGNAL
TO ACTUATOR
WITH POSITIONER
1.38 barg AIR
SUPPLY
BENCH
RANGE
(barg)
0.2-1.0 barg SIGNAL
TO ACTUATOR
WITH POSITIONER
1.38 barg AIR
SUPPLY
Max CL
IV
Shutoff
Pressure
Max CL
VI
Shutoff
Pressure
Max CL
IV
Shutoff
Pressure
Max CL
VI
Shutoff
Pressure
Max CL
IV
Shutoff
Pressure
Max CL
VI
Shutoff
Pressure
Max CL
IV
Shutoff
Pressure
Max CL
VI
Shutoff
Pressure
6.4 12.7
32 0.3-1.0 61 --- 99 --- 0.2-0.9 61 --- 99
(1)
---
32 0.5-1.0 99 --- 99
(1)
--- 0.2-0.7 99
(1)
--- 99
(1,2)
---
7.9 12.7
32 0.3-1.0 --- 28 --- 71 0.2-0.9 --- 28 --- 99
(1)
32 0.5-1.0 --- 71 --- 99 0.2-0.7 --- 92 --- 99
(1,2)
9.5 12.7
32 0.3-1.0 31 19 62 50 0.2-0.9 31 19.1 99 97
32 0.5-1.0 62 50 93 81 0.2-0.7 77 65 99
(1)
99
(1)
54 0.6-1.0 99
(1)
99
(1)
99
(1,2)
99
(1,2)
0.2-0.7 --- --- --- ---
20.6 12.7
32 0.3-1.0 7.7 1.3 15.5 9.1 0.2-0.9 7.7 1.3 27 20
32 0.5-1.0 15.5 9.1 23 16.8 0.2-0.7 19.5 12.9 38 32
54 0.5-1.0 23 17.0 35 28 0.2-0.7 29.5 23 59 52
54 0.8-1.0 47 40 59 52 --- --- --- --- ---
70 0.7-1.0 56 49 72 65 --- --- --- --- ---
1. The maximum shutoff pressure when using ENVIRO-SEAL packing is defined by: nP = Table Value - [1112/(Port Diameter)
2
]. These table values should not be modified by this formula and
the maximum nP of 51 bar should be used for ENVIRO-SEAL packing.
2. The maximum shutoff pressure when using Flexible Graphite packing is defined by: nP = Table Value - [5337/(Port Diameter)
2
]. These table values should not be modified by this formula
and the maximum nP of 99 bar should be used for Flexible Graphite packing.
Table18.AllowablePressureDrops(psi)
PORT
DIA. (in)
PLUG
TRAVEL
(in)
ACT
TYPE
AIR-TO-OPEN ACTION AIR-TO-CLOSE ACTION
BENCH
RANGE
(psig)
3-15 psig SIGNAL TO
ACTUATOR
WITH POSITIONER
20 psig AIR SUPPLY
BENCH
RANGE
(psig)
3-15 psig SIGNAL TO
ACTUATOR
WITH POSITIONER
20 psig AIR SUPPLY
Max CL
IV
Shutoff
Pressure
Max CL
VI
Shutoff
Pressure
Max CL
IV
Shutoff
Pressure
Max CL
VI
Shutoff
Pressure
Max CL
IV
Shutoff
Pressure
Max CL
VI
Shutoff
Pressure
Max CL
IV
Shutoff
Pressure
Max CL
VI
Shutoff
Pressure
0.25 0.50
32 5-15 887 --- 1440 --- 3-13 887 --- 1440
(1)
---
32 7-15 1440 --- 1440
(1)
--- 3-10 1440
(1)
--- 1440
(1,2)
---
0.3125 0.50
32 5-15 --- 418 --- 1033 3-13 --- 418 --- 1440
(1)
32 7-15 --- 1033 --- 1440 3-10 --- 1341 --- 1440
(1,2)
0.375 0.50
32 5-15 452 278 905 730 3-13 452 278 1440 1409
32 7-15 905 730 1357 1182 3-10 1131 956 1440
(1)
1440
(1)
54 9-15 1440
(1)
1440
(1)
1440
(1,2)
1440
(1,2)
3-10 --- --- --- ---
0.8125 0.50
32 5-15 113 19 226 132 3-13 113 19 396 301
32 7-15 226 132 339 245 3-10 283 188 565 471
54 7-15 343 248 514 419 3-10 428 334 856 762
54 11-15 685 591 856 762 --- --- --- --- ---
70 10-15 815 720 1048 953 --- --- --- --- ---
1. The maximum shutoff pressure when using ENVIRO-SEAL packing is defined by: nP = Table Value - [25/(Port Diameter)
2
]. These table values should not be modified by this formula and the
maximum nP of 750 psi should be used for ENVIRO-SEAL packing.
2. The maximum shutoff pressure when using Flexible Graphite packing is defined by: nP = Table Value - [120/(Port Diameter)
2
]. These table values should not be modified by this formula and
the maximum nP of 1440 psi should be used for Flexible Graphite packing.