Data Sheet

8510/8510B Valve
D100066X012
Product Bulletin
51.6:edisc (EMA)
February 2013
3
ENVIRO-SEAL Packing System Specifications
Available Packing
J ENVIRO-SEAL PTFE Packing System
J ENVIRO-SEAL Graphite Packing System
Maximum Temperature/Pressure Limits
(1)
Maximum Application Temperature/Pressure Limits
to meet EPA Fugitive Emission Standard of 100
ppm
(2):
For ENVIRO
-
SEAL PTFE Packing Systems: Up to 232C
(450F) at the ASME class rating of the valve.
For ENVIRO
-
SEAL Graphite Packing Systems: Up to
316C(600F) at the ASME c lass rating of the valve
Material Temperature Range:
For ENVIRO
-
SEAL PTFE Packing Material:
-46 to 232C(-50to450F)
For ENVIRO
-
SEAL Graphite Packing Material:
Up to 316C(600F)
Construction Materials
(3)
PTFE Packing S ystems:
Packing Rings: PTFE V-ring
(4)
Male and Female Adaptor Rings:Carbon-filled PTFE
V-ring
Anti
-
Extrusion Rings: High strength polymer
Packing Box Rings: S 31600 (316 SST)
Graphite Packing Systems:
Packing Rings: Graphite
Anti
-
Extrusion Rings: Carbon
Packing Box Rings: S 31600 (316 SST)
Spring Pack Components:
O
-
Ring: Nitrile. The O-ring serves as an assembly
conveniencetoholdthespringsinpositiononthe
follower.
Packing Follower: S31600withcarbon-filled PTFE liner
Springs: N07718
Packing Flange: S31600 (316 SST)
Packing Box Studs: Strain-hardened S31600,
SA-193-B8M
Packing Box Nuts: S31600 SA-194-8M
1. The pressure/temperature limits in this bulletin and any applicable standard or code limitation for valve should not be exceeded.
2. The Environmental Protection Agency (EPA) has set a limit of 100 parts per million (ppm) for fugitive emissions from a valve.
3. For other materials of construction, see table 3.
4. In vacuum service it is not necessary to reverse the ENVIRO-SEAL PTFE packing rings.
Features (continued)
Improved Environmental Capabilities–The optional
ENVIRO-SEALt packing systems, shown in figure 6,
are designed with very smooth stem surfaces, and
live loading provides improved sealing, guiding, and
loading force transmission. The seal of the
ENVIRO-SEAL system can control emissions to
below the EPA (Environmental Protection Agency)
limit of 100 ppm (parts per million) for valves.
Lost Motion Minimized–For 8510, the taper pin/disc
connection and the splined valve shaft with
clamped lever and single pivot linkage reduce lost
motion between the actuator and valve. For 8510B,
the taper key/disc connection and the splined valve
shaft with clamped lever and single pivot linkage
reduce lost motion between the actuator and valve.
Greater Capacities and Lower Operating
Torques–The contoured disc inc reases flow
capacity and reduces operating torque at peak
angles of disc opening.