Table 2. Additional Specifications (Action Air‐to‐Close)
Size
Spring Set/
Quantity
Travel Spring Range
Effective Diaphragm Area
(1)
Maximum Output Thrust
(Maximum Actuator Stem
Force)
(2)
mm Inch Bar Psig cm
2
Inches
2
N Lb
30
217/3
218/5
218/7
16 - - -
0.3 ‐ 1.1 4 ‐ 16 160 24.8 7840 1760
1.3 ‐ 2.0 19 ‐ 29 160 24.8 6400 1440
1.8 ‐ 2.9 26 ‐ 42 160 24.8 4960 1120
30E
217/3
218/5
218/7
- - - 0.75
0.3 ‐ 1.3 4 ‐ 19 160 24.8 7520 1690
1.3 ‐ 2.2 19 ‐ 32 160 24.8 6080 1360
1.8 ‐ 3.0 26 ‐ 44 160 24.8 4800 1070
34
219/3
212/5
212/7
16 - - -
0.3 ‐ 1.1 4 ‐ 16 400 62.0 19,600 4400
0.9 ‐ 1.7 13 ‐ 25 400 62.0 17,200 3840
1.3 ‐ 2.3 19 ‐ 33 400 62.0 14,800 3350
34E
219/3
212/5
212/7
- - - 0.75
0.3 ‐ 1.3 4 ‐ 19 400 62.0 18,800 4220
0.9 ‐ 1.8 13 ‐ 26 400 62.0 16,800 3780
1.3 ‐ 2.5 19 ‐ 36 400 62.0 14,000 3160
40
212/3
213/6
214/7
32 - - -
0.4 ‐ 1.3 6 ‐ 19 390 60.5 18,300 4110
0.8 ‐ 1.8 12 ‐ 26 390 60.5 16,400 3690
1.2 ‐ 2.4 17 ‐ 35 390 60.5 14,000 3150
40E
212/3
213/6
214/7
- - - 1.125
0.4 ‐ 1.2 6 ‐ 17 390 60.5 18,700 4230
0.8 ‐ 1.7 12 ‐ 25 390 60.5 16,800 3750
1.2 ‐ 2.3 17 ‐ 33 390 60.5 14,400 3270
213/4
214/5
214/7
- - - 1.5
0.3 ‐ 1.0 4 ‐ 15 380 58.9 19,000 4240
0.6 ‐ 1.5 9 ‐ 22 380 58.9 17,100 3830
0.9 ‐ 2.1 13 ‐ 30 380 58.9 14,800 3360
213/4
214/5
214/7
- - - 2
0.2 ‐ 1.2 3 ‐ 17 370 57.4 17,800 4220
0.5 ‐ 1.7 7 ‐ 25 370 57.4 15,900 3560
0.7 ‐ 2.4 10 ‐ 35 370 57.4 13,300 2980
45
221/8
221/12
223/12
32 - - -
0.8 ‐ 1.6 12 ‐ 23 790 122 34,800 7810
1.2 ‐ 2.5 17 ‐ 36 790 122 27,600 6220
1.5 ‐ 3.1 22 ‐ 45 790 122 22,900 5120
45E
221/8
221/12
223/12
- - - 1.125
0.8 ‐ 1.6 12 ‐ 23 790 122 34,800 7810
1.2 ‐ 2.3 17 ‐ 33 790 122 29,200 6590
1.5 ‐ 3.0 22 ‐ 44 790 122 23,700 5250
221/8
221/12
223/12
- - - 1.5
0.5 ‐ 1.4 7 ‐ 20 780 121 35,900 8110
0.8 ‐ 2.2 12 ‐ 32 780 121 29,600 6650
1.0 ‐ 2.7 15 ‐ 39 780 121 25,700 5810
221/8
221/12
223/12
- - - 2
0.5 ‐ 1.7 7 ‐ 25 770 119 33,100 7380
0.7 ‐ 2.5 10 ‐ 36 770 119 26,900 6070
0.9 ‐ 3.1 12 ‐ 45 770 119 22,300 5000
1. Effective diaphragm area at 0% valve travel from seat.
2. Based upon 6 bar operating pressure to the diaphragm and valve travel at 0% from seat. This does not consider limitation to the valve such as stem buckling load. Consult your Emerson
Process Management sales office for details.
Specifications
Refer to table 1 for Specifications of the 3024C actuator. See the actuator nameplate (figure 3) for specific information
about your actuator.