Data Sheet
3024C Actuator
D103051X012
Product Bulletin
61.1:3024C
March 2012
7
Table 4. Additional Specifications (Action - Air Extends Stem)
SIZE
SPRING
SET/QTY
TRAVEL SPRING RANGE
EFFECTIVE DIAPHRAGM
AREA
(1)
MAXIMUM OUTPUT
THRUST (MAXIMUM
ACTUATOR STEM FORCE)
(2)
mm Inch Bar Psig cm
2
Inches
2
N Lb
30
217/3
218/5
218/7
16 ---
0.3 - 1.1 4-16 160 24.8 7840 1760
1.3 - 2.0 19 - 29 160 24.8 6400 1440
1.8 - 2.9 26 - 42 160 24.8 4960 1120
30E
217/3
218/5
218/7
--- 0.75
0.3 - 1.3 4-19 160 24.8 7520 1690
1.3 - 2.2 19 - 32 160 24.8 6080 1360
1.8 - 3.0 26 - 44 160 24.8 4800 1070
34
219/3
212/5
212/7
16 ---
0.3 - 1.1 4-16 400 62.0 19,600 4400
0.9 - 1.7 13 - 25 400 62.0 17,200 3840
1.3 - 2.3 19 - 33 400 62.0 14,800 3350
34E
219/3
212/5
212/7
--- 0.75
0.3 - 1.3 4-19 400 62.0 18,800 4220
0.9 - 1.8 13 - 26 400 62.0 16,800 3780
1.3 - 2.5 19 - 36 400 62.0 14,000 3160
40
212/3
213/6
214/7
32
---
0.4 - 1.3 6-19 390 60.5 18,300 4110
0.8 - 1.8 12 - 26 390 60.5 16,400 3690
1.2 - 2.4 17 - 35 390 60.5 14,000 3150
40E
212/3
213/6
214/7
--- 1.125
0.4 - 1.2 6-17 390 60.5 18,700 4230
0.8 - 1.7 12 - 25 390 60.5 16,800 3750
1.2 - 2.3 17 - 33 390 60.5 14,400 3270
213/4
214/5
214/7
--- 1.5
0.3 - 1.0 4-15 380 58.9 19,000 4240
0.6 - 1.5 9-22 380 58.9 17,100 3830
0.9 - 2.1 13 - 30 380 58.9 14,800 3360
213/4
214/5
214/7
--- 2
0.2 - 1.2 3-17 370 57.4 17,800 4220
0.5 - 1.7 7-25 370 57.4 15,900 3560
0.7 - 2.4 10 - 35 370 57.4 13,300 2980
45
221/8
221/12
223/12
32 ---
0.8 - 1.6 12 - 23 790 122 34,800 7810
1.2 - 2.5 17 - 36 790 122 27,600 6220
1.5 - 3.1 22 - 45 790 122 22,900 5120
45E
221/8
221/12
223/12
--- 1.125
0.8 - 1.6 12 - 23 790 122 34,800 7810
1.2 - 2.3 17 - 33 790 122 29,200 6590
1.5 - 3.0 22 - 44 790 122 23,700 5250
221/8
221/12
223/12
--- 1.5
0.5 - 1.4 7-20 780 121 35,900 8110
0.8 - 2.2 12 - 32 780 121 29,600 6650
1.0 - 2.7 15 - 39 780 121 25,700 5810
221/8
221/12
223/12
--- 2
0.5 - 1.7 7-25 770 119 33,100 7380
0.7 - 2.5 10 - 36 770 119 26,900 6070
0.9 - 3.1 12 - 45 770 119 22,300 5000
1. Effective diaphragm area at 0% valve travel from seat.
2. Based upon 6 bar operating pressure to the diaphragm and valve travel at 0% from seat. This does not consider limitation to the valve such as stem buckling load. Consult your Emerson
Process Management sales office for details.