Epsilon EP Specifications
Epsilon EP Series
Power Requirements
(240 Vac for rated performance)
Model AC Power
DC Power
(UL Pending)
EP202
20 Vac-264 Vac,
1 Ø, 47-63 Hz
10 Vdc - 340 Vdc
Type TN (Grounded)
Installation
Category III
EP204
EP206
EP209
90 Vac - 264 Vac
1 Ø, 47-63 Hz
140 Vdc - 340 Vdc
EP216
90 Vac - 264 Vac
3 Ø, 47-63 Hz
140 Vdc - 340 Vdc
90 Vac - 264 Vac
1 Ø, 47-63 Hz
SCCR
(Short Circuit Current Rating)
10,000 Symmetrical RMS Amps
Solid State Motor
Overload Protection
115% of rated FLA
Rated Output Current and Power
Model Continuous Power Continuous Current Peak Current
EP202 775 W 2.2 A RMS at 40°C or 50°C 4.4 A RMS
EP204 1275 W
4.0 A RMS at 40° C
3.6 A RMS at 50° C
8 A RMS
EP206 1775 W
6.5 A RMS at 40° C
5.2 A RMS at 50° C
13 A RMS
EP209 2325 W
9.0 A RMS at 40° C
7.7 A RMS at 50° C
18 A RMS
EP216
3 Ø Input
4800 W
16.0 A RMS at 40° C
16.0 A RMS at 50° C
32 A RMS
EP216
1 Ø Input
2325 W
16.0 A RMS at 40° C
16.0 A RMS at 50° C
32 A RMS
Continuous Input Current
(AC Input)
Model Continuous Current Inrush Current
EP202 5.0 A RMS at 40° C or 50° C 40 A RMS for 5 ms
EP204
8.5 A RMS at 40° C
7.6 A RMS at 50° C
65 A RMS for 5 ms
EP206
12.0 A RMS at 40° C
9.6 A RMS at 50° C
100 A RMS for 5 ms
EP209
16.0 A RMS at 40° C
13.6 A RMS at 50° C
34 A RMS for 5 ms
EP216, 3 Ø Input
16.0 A RMS at 40° C
16.0 A RMS at 50° C
34 A RMS for 5 ms
EP216, 1 Ø Input