The following paragraphs provide details of motor connections. When motor power cables are long, 100ft. [30 m], a
ferrite (Control Techniques p/n 157016-13, Steward p/n 28A3851-0A2 or equivalent) installed on the three phase
conductors but not the shield, near J1 can significantly reduce high frequency switching harmonics that in some
cases can cause communications and encoder errors, see figures below. Maximum cable length is 200 ft [60 m].
With the Epsilon EP202/204/206/209 drive the J1 terminals are suitable for one 18 AWG to 14 AWG or ISO 0,75 to
ISO 2,5 stranded conductors. The Epsilon EP216 drive J1 terminals are suitable for one 16 AWG to 10 AWG or ISO
1,5 to ISO 6 stranded conductors. The ground/shield terminal may contain the shield and ground conductors together
if each is 16 AWG or ISO 0,75 or ISO 1,5. Otherwise a ferrule must be used to crimp both connectors together.
Figure 21: EP202-206 Ferrite Placement with Cable Lengths Longer Than 100 FT.
Figure 22: EP209 Ferrite Placement with Cable Lengths Longer Than 100 FT.
Motor
Power Connections
R
S
T
Ground
Connector Shell
Ferrite
EP204-I00-0000
9606XX-XX A1
SN 0610E014
Front View
24 Vdc
R
S
T
MOTOR
L1
L2
PE
Motor
Power Connections
R
S
T
Ground
Connector Shell
Ferrite
Front View
logic
R
S
T
MOTOR
EP209-I00-0000
9606XX-XX A1
SN 0610E014