Installation manual
71
Setting Up Parameters
Shunt Control Group
Shunt Power RMS
This parameter models the thermal heating and cooling of the drive internal shunt. This parameter indicates the percent
of shunt capacity utilization. When this value reaches 100 percent the drive will generate an RMS Shunt Power Fault.
Information Tab
ID Group
Firmware Revision
Displays the revision of the firmware in the drive you are currently online with.
Serial Number
Displays the serial number of the drive with which you are currently online.
Interface Revision
Displays the application interface revision.
Time Group
Power Up Time Total
Total amount of times the drive has been powered up since leaving the factory.
Power Up Count
Number of times the drive has been powered up since leaving the factory.
Power Up Time
Amount of time the drive has been powered up since last power up.