Installation manual

69
Setting Up Parameters
Note: This does not limit the D/A output voltage
Analog Min Value
The lower Value in the point set (Value,Voltage):
•RW
Units are defined by the source selected
Note: This does not limit the D/A output value
Analog Min Voltage
The lower Voltage in the point set (Value,Voltage):
RW Voltage units (volts) -10.000 to +10.000
Units are defined by the source selected
Note: This does not limit the D/A output voltage
Online Tab
Analog Out Feedback
This is a display of the real time status of the two analog outputs in volts. It is only available when you are online with a
device.
Status View
This view has two tabs, the Status Online tab displays the drive status in real time and the Information tab displays
general information about the drive/module the user is online with.
Status Online Tab
The information in this view is divided into five categories: Position, Velocity, Torque, Drive Status and Index.
Figure 53: Status View - Status Online Tab - Online
The information in this view is for diagnostics purposes only and cannot be changed from within this view.
Position Group
Pulse Position Input
This parameter returns the total number of actual pulses received on the pulse input hardware. This value is active in all
operating modes.