Installation manual
13
Operational Overview
Figure 14: Setup View - Pulse Mode
High Performance Gains Enable check box in PowerTools Pro software is typically enabled when Pulse mode is
used (the default is enabled).
Interpretation Mode Group
Pulse/Pulse Interpretation
In Pulse/Pulse interpretation, pulses received on the A channel are interpreted as positive changes to the Pulse Position
Input. Pulses received on the B channel are interpreted as negative changes to the Pulse Position Input.
Figure 15: Pulse/Pulse Signals, Differential Inputs
Pulse/Direction Interpretation
In Pulse/Direction interpretation, pulses are received on the A channel and the direction is received on the B channel. If
the B is high, pulses received on the A are interpreted as positive changes to the Pulse Position Input. If the B is low,
pulses received on the A are interpreted as negative changes to the Pulse Position Input.
Motion occurs
on rising edge
Channel A (CW)
Channel B (CCW)
+ Pulse Input
- Pulse Input