Installation Manual

2.125"
[53.98]
2.4"
[60.96]
Unprotected Pair 2
Unprotected Pair 1
Protected Pair 2
Protected Pair 1
Keying Pin
Even TerminalsOdd Terminals
Field Side
Electronics Side
9
7
5
3
1
10
8
6
4
2
1.0”
[25.40]
{
}
}
{
APPLICATIONS PART NUMBER
24■V■Horn,■Strobe,■Bell PHC-043■&■PCB1B-WKEY
70■V■Speaker■Lines PHC-SP70■&■PCB1B-WKEY
MODEL
OPERATING
VOLTAGE
CLAMPING
VOLTAGE
PHC-015 12■VDC 15■VDC
PHC-020 18■VDC 20■VDC
PHC-030 24■VDC 30■VDC
PHC-036 30■VDC 36■VDC
PHC-043■ 36■VDC 43■VDC
PHC-060 52■VDC 60■VDC
PHC-SP70 70■VDC *100■VDC
PHC-130RMS 120■VDC *150■VDC
Ordering Information
How to Specify the Appropriate Model
Emerson Network Power Contact information
Surge■Protection
100■Emerson■Parkway
Binghamton,■NY■13905
T:■(607)■721-8840
T:■(800)■288-6169
F:■(607)■722-8713
E:■SurgeTech@Emerson.com
IO-50100■5/14■Rev.■4■Printed■in■USA
www.EmersonNetworkPower.com/Surge
While■every■precaution■has■been■taken■to■ ensure■accuracy■ and■completeness■herein,■Emerson■ Network■Power■Surge■ Protection■assumes■no■responsibility,■and■ disclaims■all■liability,■for■ damages■
resulting■from■use■of■this■information■or■for■any■errors■or■omissions.■Specifications■are■subject■to■change■without■notice.
2.3”
[58.42]
PHC Series
3.7”
[93.98]
PCB1B-WKEY
Emerson■Network■Power,■the■Emerson■Network■Power■logo■and■Edco■are■trademarks■
and■service■marks■of■Emerson■Electric■Co.■©2014■Emerson■Electric■Co.
*Not UL Listed
(for■Horn,■Bell,■Strobes)
(for■120■V■Signal■Lines)
Seulement■le■personnel■qualifié■doit■installer■
ou■ maintenir■ ce■ systéme.■ Des■ précautions■
de■sécurité■en■électricité■doivent■être■suivis■
lors■ de■ l’installation■ ou■ de■ la■ maintenance■
de■ cet■ equipement.■ Pour■ eviter■ tout■ risque■
de■choc■électrique,■débranchez■et■verouiller■
toutes■ les■ sources■ d’alimentation■ de■ cet■
equipement■avant■de.
Only■ qualified■ personnel■ should■ install■ or■
service■ this■ system.■ Electrical■ safety■ pre-
cautions■ must■ be■ followed■ when■ installing■
or■ servicing■ this■ equipment.■ To■ prevent■ risk■
of■ electrical■ shock,■ turn■ off■ and■ lock■ out■ all■
power■ sources■ to■ the■ unit■ before■ making■
electrical■connections■or■servicing.
V
DANGER!
Ground■Terminal■1■or■10■to■Building■Approved■Ground■■
(preferably■AC■Power■safety■ground).
DO■NOT■daisy■chain■grounds.■NOT■intended■for■shield■termination.■
Install■ground■in■accordance■with■all■applicable■codes.
PCB1B-WKEY
Installation Instructions
Terminal Assignments