Installation Manual

Edco CX Series
CCTV & Data Applications/Coax
The Edco CX06-M, CX06-MI and CX06-MI-SBL Surge Protective Devices (SPDs)
implement three-stage hybrid technology. The SPDs address over-voltage
transients with a primary Gas Discharge Tube (GDT) and secondary Silicon
Avalanche Diode (SAD) components. Over-current protection, e.g. sneak and fault
currents, are mitigated with solid-state resettable fuses — PTCs.
The Edco CX06-M, CX06-MI and CX06-MI-SBL SPDs are designed in accordance
with NFPA 780 (2004 edition) requirements, with up to 20 kA of surge current
capability. The Edco CX06-MI and CX06-MI-SBL models have an isolated ground
and is recommended for use at the camera-end.
General Technical Specifications
Ordering Information
*Other configurations available,
please contact factory.
Features
Sneak/fault current protection
Low insertion loss
Shielded case
Models with isolated ground
5 year warranty
Operating Voltage 5 VDC
Clamping Voltage 6 VDC
Operating Current 0.15 A
Peak Surge Current 20 kA (8 x 20 μs)
Frequency Range 0 to 20 MHz
Insertion Loss < 0.1 dB at 20 MHz
Response Time < 0.5 ns
SPD Technology GDT, SAD, w/ Series PTC
Connection Type BNC, 50/75 Ohm
Operating Temperature -40°C to +85°C
Dimensions (in / mm) M = 1.5˝ H x 1.0˝ W x 3.25˝ L
[38.1 x 25.4 x 82.55 mm]
MI = 1.5˝ H x 1.0˝ W x 4.0˝ L
[38.1 x 25.4 x 101.6 mm]
SBL = 1.7˝ H x 1.4˝ W x 2.8˝ L
[43.18 x 35.56 x 71.12 mm]
Weight (oz / kg) M = 2.3 oz [0.07 kg]
MI = 3 oz [0.09 kg]
SBL = 3 oz [0.09 kg]
Certifications UL 497B Listed
Head-End CX06-M
Camera-End
CX06-MI
CX06-MI-SBL
CX06-MI-SBL
CX06-MI
CX06-M
Caution
Do not place this product in service on any signal line capable of supplying more than 150 mA continuously.
Attention
Ne pas placer ce produit dans le service sur une ligne de signal capable de fournir en permanence plus de
150 mA.