Brochure
Page 5
panelBoards
POWERPLEX™ FACTORY SEALED LIGHTING DISTRIBUTION PANELBOARDS:
EXPLOSIONPROOF, DUST-IGNITIONPROOF, WATERTIGHT, CORROSION RESISTANT
• CertificationsandCompliances
UL Standards: ANSI/UL 67, ANSI/ISA 12.12.01,
ANSI/UL 1203, ANSI/UL 60079-0, ANSI/
UL60079-1, ANSI/UL60079-7
CSAStandards:C22.2No.29,C22.2No.0,
C22.2No.213,CANE60079-0,
CANE60079-7,CANE60079-1
cCSAusCertified:039199
ClassI,Division2GroupB,C,D
ClassI,Zone1AExdeIIB+H
2
T5
ClassII,Division1,GroupF,G
ClassIII
ExdeIIB+H
2
Type 4X, IP66
• Indoorandoutdoorprotectionandcontrolofelectricalequipmentandcircuitsthatissuitableforuseonlighting,heattraceandpower
circuits. Ideal for placement in wet, corrosive environments or where flammable gases or vapors are likely to be present.
• ThePowerPlexpanelboardfeaturesaground-breakingdesignthatusesindividualbreakerhousingstominimizethedowntimeandcosts
associated with servicing circuit breakers in hazardous locations.
SHIPPED IN 5 BUSINESS DAYS.
(Maximum 5 panels per order. No GFI, EPD or HID breakers.)
INCLUDE THE COMPLETED BREAKER SCHEDULE FORM WITH ALL ORDERS. ALL BREAKER POSITIONS MUST BE FILLED.
Internal Actuation Only
Service and
Maximum Amps Cable Range Wiring System
Number of
Breakers Panel Size Circuits Catalog Number
100 Amps Main Lugs Only
4/0to#14AWG 120/208V3ØAC
12 C 12
RQSC131L12QRP
100or60AmpsMainBreaker RQSC131M12QRP
100 Amps Main Lugs Only
24 D 24
RQSD131L24QRP
100or60AmpsMainBreaker RQSD131M24QRP
OptionalExternalActuation
Service and
Maximum Amps Cable Range Wiring System
Number of
Breakers Panel Size Circuits Catalog Number
100 Amps Main Lugs Only
4/0to#14AWG 120/208V3ØAC
12 C 12
RQSC131L12QRPEX
100or60AmpsMainBreaker RQSC131M12QRPEX
100 Amps Main Lugs Only
24 D 24
RQSD131L24QRPEX
100or60AmpsMainBreaker RQSD131M24QRPEX
D2P FACTORY SEALED CIRCUIT BREAKER PANELBOARDS:
EXPLOSIONPROOF, DUST-IGNITIONPROOF, WATERTIGHT, CORROSION-RESISTANT
• CertificationsandCompliances
UL Standard: UL 877, UL 1203
ULClassified:E77137
ClassI,Division2,GroupsB ,C,D
ClassII,Division1and2,GroupsE,F,G
ClassIII
NEMA3,3R,4,4X,5,7BCD,9EFG,12
• Protectionandcontrolofelectricalequipmentandcircuitssuchaslightingandheattracinginhazardouslocationsorindamp,wetor
corrosive conditions.
• DesignedforuseinClassI,Division2areaswhereignitablevaporsorgasesmaybepresentunderunusualconditions,orinClassII,
Division1areaswherecombustibledustsarepresent.
SHIPPED IN 10 BUSINESS DAYS.
(Maximum 5 panels per order. No GFI, EPD or HID breakers.)
INCLUDE THE COMPLETED BREAKER SCHEDULE FORM WITH ALL ORDERS.
Main Lug
Maximum Amps
Cable
Range
Wiring
System
Number of
Breakers
Panel
Size Circuits
Catalog
Number
250 250MCMto6
Number 4
120/240VAC
12 A 12 D2P4A12QRP
24 B 24 D2P4B24QRP
36 C 36 D2P4C36QRP
Number 5
120/208VAC
12 A 12 D2P5A12QRP
24 B 24 D2P5B24QRP
36 C 36 D2P5C36QRP
R
C US
ForGroupsBandC,allconduitsmustbesealedadjacenttoenclosure.