Specifications

Reference Manual
MHM-97408, Rev. 2
June 2008
CSI 9420
B-2
Ordinary Location
Certification for FM
As standard, the transmitter has been examined and tested to determine that
the design meets basic electrical, mechanical, and fire protection
requirements by FM, a nationally recognized testing laboratory (NRTL) as
accredited by the Federal Occupational Safety and Health Administration
(OSHA).
ATEX Directive (94/9/EC)
Emerson Process Management complies with the ATEX Directive.
Electro Magnetic Compatibility (EMC) (2004/108/EC)
All Models: EN 61326-1, 61326-2-3: 2006
Radio and Telecommunications Terminal Equipment Directive
(R&TTE)(1999/5/EC)
Emerson Process Management complies with the R&TTE Directive.
HAZARDOUS
LOCATIONS
CERTIFICATES
North American Certifications
Factory Mutual (FM) Approvals, pending
I5 FM Non-incendive
Zone Marking: Class I, Zone 2, AEx n llC
Temperature Codes T4 (T
amb
= -50 to 70 °C)
T5 (T
amb
= -50 to 40 °C)
Non-incendive for Class I, Division 2, Groups A, B, C, and D.
Ambient temperature limits: -34 to 80 °C
For use with Rosemount power module pack P/N 753-9220-XXXX (MHM
P/N 89002) only.
Enclosure Type 4X / IP66
CSA - Canadian Standards Association, pending
I6 CSA for Class I, Division 2, Groups A, B, C, and D.
Temp Code T3C
Enclosure Type 4X / IP66
For use with Rosemount SmartPower option
00753-9220-XXXX only.
European Certifications
CE mark, pending
ATEX, Zone 2, pending (for 2.4 GHz only)
ATEX Category Marking:
II 3G Ex nA nL HC T5 (-50
o
C < T
a
< +40
o
C)