Product data
www.assetweb.com7
Machinery Health
™
Management October 2014
Functional Specifications
Inputs
Accelerometer 1 DC Bias Range: 2 - 3 Vdc
DC Input Range: 0 - 5 Vdc
AC Input Range: 2.5 Vpeak equivalent to 100 g’s peak (980 m/s
2
peak)
Accelerometer 2 DC Bias Range: 2 - 3 Vdc
DC Input Range: 0 - 5 Vdc
AC Input Range: 2.5 Vpeak equivalent to 100 g’s peak (980 m/s
2
peak)
Temperature DC Input Range: -30° to + 121°C (-22°F to 250°F )
Standard Outputs
Machinery Health Values Velocity overall (1 or 2 sensors)
PeakVue overall (1 or 2 sensors)
Temperature (1 sensor only)
Transmitter Health Values Ambient temperature
Supply voltage
Sensor bias voltage (1 or 2 sensors)
Multiple internal alerts indicate the status of device health
Advanced Diagnostic Outputs (optional)
Energy bands Rotor vibration (2 - 65 Hz)
Rotor harmonics (65 - 300 Hz)
High Frequency (300 - 1,000 Hz)
Thumbnail Spectrum Fmax: 150, 300, 600, or 1,000 Hz
High Resolution Vibration Spectrum Fmax: 1,000 Hz
Resolution: 400, 800 or 1,600 lines
Snapshot or Averaged (4 readings)
High Resolution Vibration Waveform All measurements based on high resolution waveform with 4,096 points
High Resolution PeakVue Spectrum Bandwidth: 1,000 - 20,000 Hz
Fmax: 1,000 Hz
Resolution: 1,600 lines
Snapshot of impacting on machine
High Resolution PeakVue Waveform Sampled at 51,200 Hz;
High resolution with 4,096 points
Display
Units English, metric or SI
Local Display The optional ve-digit integral LCD display provides readout of
HART parameters in engineering units (°F, °C, in/sec, mm/sec, g’s and m/s
2
).
Display updates for each transmission
Maximum update rate - once per minute
Update Rate Standard: 1 min to 60 min (User selectable)
Power Save: up to 24 hours (User selectable)
Operating Conditions
Relative Humidity 0 - 95%
Temperature Storage Temperature: -40°C to 85°C (-40°F to 185°F)
Operating Temperature without LCD meter: -40°C to 85°C (-40°F to 185°F)
Operating Temperature with LCD display: -20°C to 80°C (-4°F to 176°F)
Device software version 6.0 or higher required for 400 line spectrum.