Data Sheet
CS800 Series Specifi cations
The distinctive swirl pattern cast into every actuator
casing uniquely identifi es the regulator as part of the
Fisher
®
brand Commercial Service Regulator family
and assures you of the highest-quality engineering,
performance, and support traditionally associated
with Fisher, Francel™, and Tartarini™ regulators.
Visit www.fishercommercialservice.com to access
interactive applications.
For further information, visit www.emersonprocess.com/regulators
TM
T
M
Our Global Natural Gas Product Brands:
D351369X012 © 2011, 2014 Emerson Process Management Regulator Technologies, Inc. All rights reserved. Printed in the U.S.A. 11/14.
Fisher, Francel, Tartarini, Emerson Process Management, and the Emerson Process Management design are marks of one of the Emerson
Process Management group of companies. All other marks are the property of their respective owners.
North America
McKinney, Texas 75070 USA
Tel: +1 800 558 5853
Outside U.S. +1 972 548 3574
Europe
Bologna 40013, Italy
Tel: +39 051 419 0611
Chartres 28008, France
Tel: +33 2 37 33 47 00
Asia-Pacific
Singapore 128461, Singapore
Tel: +65 6770 8337
Emerson Process Management Regulator Technologies, Inc.
Largest Overpressure Protection Breadth in the Industry
Operation: Direct-Operated, Pressure Reducing
Body Sizes and End Connections:
1-1/4, 1-1/2, 2 NPT, Rp 2;
NPS 2 / DN 50 (CL125 FF, CL150 FF, CL150 RF, PN 10/16)
Maximum Inlet Pressure: up to 175 psig / 12.1 bar
Maximum Outlet Pressure: up to 15 psig / 1.0 bar
Outlet Pressure Ranges:
3.5 in. w.c. to 10 psig / 9 to 690 mbar
Temperature Capabilities: -20 to 150°F / -30 to 66°C
Spring Case Vent Connection: 1 or 2-1/2 NPT
Pressure Registration: Internal and External
Body Material: Gray Cast Iron, Ductile Iron and Steel
Overpressure Protection Options:
Internal Relief
High Capacity Relief
Secondary Seat Protection
Integral True-Monitor Protection
Slam-Shut Protection
Secondary Seat™ Protection - Provides a
solution to the most common cause of regulators
failing to shutoff by employing a secondary
seating surface for shutoff if the primary orifi ce
seating surface becomes damaged or blocked.
Internal Relief - Minimizes downstream pressure
buildup by relieving gas through the diaphragm
assembly and out the 1 NPT vent to atmosphere
in the event of an overpressure situation.
High Capacity Relief - Large 2-1/2 NPT vent
provides a signifi cant increase in relieving
capacity and level of overpressure protection to
the downstream system.
Integral True-Monitor™ Protection - Combines
the operation of a conventional two-regulator
wide-open monitor set into one device without
the need for a downstream control line.
Slam-Shut Protection - Provides an integral
slam-shut module that shuts off the fl ow of gas
to the downstream system in an overpressure or
underpressure situation.
Slam-Shut Protection
Provides an integral