Data Sheet

Bulletin 71.1:CS200
24
ORIFICE SIZE REGULATOR SET PRESSURE
MAXIMUM INLET PRESSURE TO KEEP OUTLET PRESSURE AT OR BELOW
(1)
4 psig / 0.28 bar 5 psig / 0.34 bar
Inch mm psig mbar psig bar psig bar
1/8 3.2
2 138
122 8.4 >125 >8.6
3/16 4.8 47 3.2 96 6.6
1/4 6.4 23 1.6 49 3.4
3/8 9.5 9 0.62 17 1.17
1. Relief value obtained by disconnecting the lever.
Table 21. Type CS200IR Internal Relief Performance Table for 2 psig / 138 mbar Setpoint
Figure 8. NPS 1 Body Type CS200IR Typical Relief Performance (Linkage Disconnect) at 2 psig / 138 mbar Set Pressure
OUTLET PRESSURE, psig / bar
INLET PRESSURE, psig / bar
4 /
0.28
4.5 /
0.31
3.5 /
0.24
3 /
0.21
5 /
0.34
1/8-INCH / 3.2 mm
ORIFICE
3/16-INCH / 4.8 mm
ORIFICE
1/4-INCH / 6.4 mm
ORIFICE
3/8-INCH /
9.5 mm ORIFICE
1/2-INCH / 13 mm
ORIFICE
10 / 0.690 20 / 1.4 30 / 2.1 40 / 2.8 50 / 3.4 60 / 4.1 70 / 4.8 80 / 5.5 90 / 6.2 100 / 6.9 110 / 7.6 120 / 8.3