Data Sheet
Bulletin 71.1:CP400
24
Table 30. CP400 Series Internal Registration Flow Capacities for 5 psig / 0.34 bar Setpoint with 1% Pressure Factor Accuracy per
Measurement Canada
ACCURACY
SETPOINT + / - 1% ABS SET RANGE
PART NUMBER /
COLOR
5 psig -0.2 psi 0.2 psi 2 to 5 psig
GE27213X012 /
Orange Stripe
0.34 bar -14 mbar 14 mbar 0.14 to 0.34 bar
CAPACITIES IN SCFH / Nm
3
/h OF 0.6 SPECIFIC GRAVITY NATURAL GAS
Inlet Pressure
Orice Size
3/16 In. / 4.8 mm 1/4 In. / 6.4 mm 3/8 In. / 9.5 mm 1/2 In. / 13 mm 3/4 In. / 19 mm
SCFH Nm
3
/h SCFH Nm
3
/h SCFH Nm
3
/h SCFH Nm
3
/h SCFH Nm
3
/h
psig bar Body Size: NPS 1-1/4 / DN 32
10 0.69 270 7.24 490 13.1 590 15.8 1500 40.2 2800 75.0
15 1.0 760 20.4 1100 29.5 2900 77.7 4300 115 6000 161
20 1.4 1000 26.8 1800 48.2 3900 105 5300 142 6000 161
25 1.7 1100 29.5 2300 61.6 4800 129 5300 142 6000 161
30 2.1 1300 34.8 2600 69.7 5000 134 5300 142 4600 123
40 2.8 1500 40.2 3000 80.4 5000 134 5300 142 3700 99.2
50 3.4 1900 50.9 3800 102 5000 134 5300 142
60 4.1 2400 64.3 4500 121 5000 134 5300 142
80 5.5 3000 80.4 5000 134 5000 134
100 6.9 3800 102 5000 134
psig bar Body Size: NPS 1-1/2 / DN 40
10 0.69 460 12.3 1000 26.8 1300 34.8 2600 69.7 2900 77.7
15 1.0 730 19.6 1500 40.2 3000 80.4 5300 142 2900 77.7
20 1.4 1100 29.5 2000 53.6 4200 113 5300 142 2900 77.7
25 1.7 1100 29.5 2300 61.6 5000 134 5300 142 2900 77.7
30 2.1 1400 37.5 2600 69.7 5500 147 5300 142 2100 56.3
40 2.8 1600 42.9 3200 85.8 6600 177 5400 145 1300 34.8
50 3.4 2100 56.3 3700 99.2 7200 193 5400 145
60 4.1 2500 67.0 4600 123 7200 193 5400 145
80 5.5 3200 85.8 5700 153 7200 193
100 6.9 6300 169
psig bar Body Size: NPS 2 / DN 50
10 0.69 370 9.92 640 17.2 260 6.97 240 6.43 810 21.7
15 1.0 670 18.0 1600 42.9 2400 64.3 4500 121 9400 252
20 1.4 1000 26.8 1900 50.9 4100 110 6400 172 9400 252
25 1.7 1100 29.5 2300 61.6 4900 131 8700 233 9400 252
30 2.1 1300 34.8 2700 72.4 5700 153 8700 233 9400 252
40 2.8 1400 37.5 3300 88.4 7500 201 8700 233 6700 180
50 3.4 1800 48.2 3700 99.2 7800 209 8700 233
60 4.1 2300 61.6 4400 118 7800 209 8800 236
80 5.5 3100 83.1 5700 153
100 6.9 3600 96.5 6800 182
Blank areas indicate where maximum operating inlet pressure for a given orice size is exceeded.
Light Gray areas indicate limited capacities due to boost effects.
Dark Gray areas show where indicated droop would be exceeded regardless of capacity.