Product data

Product Data Document
1660ds9b / D301294X012
October 2011 - Page 7
ControlWave GFC Plus
Remote Automation Solutions
www.EmersonProcess.com/Remote
CONTROLWAVE GFC PLUS STANDARD
APPLICATION PROGRAM
You can select from a variety of standard applica-
tions. Currently available are the 1 – 2 run M&R
standard application and a TeleFlow Emulator ap-
plication.
ControlWave GFC Plus is shipped with the program
(.pro le) loaded in Flash and the Flash Congura-
tion Program (FCP) also loaded.
Each run can be orice, turbine or ultrasonic
meter type
Flow calculations include the following:
AGA3-1992 with selectable AGA8 Gross or
AGA8 Detail
AGA3-1985/NX-19
AGA7/NX-19
AGA7 with selectable AGA8 Gross or AGA8
Detail
Auto Adjust AGA7/NX-19
Auto Adjust AGA7 with selectable AGA8 Gross
or AGA8 Detail
AGA9
Allows the user to select the integral sensor
assembly or an external transmitter for a single
run conguration or as run 1 in a multiple run
conguration. External transmitters can be
interfaced via RS 485 or analog inputs.
Includes run switching
Includes an auto-selector, PID ow/pressure
control algorithm per run or per station
Resides on a BSAP SCADA network
Supports a sampler and an odorizer
Hourly Historical Data Log
The Hourly Data Log holds one record for every
contract hour. Hourly logs hold 840 entries or 35
days; this ensures that the previous period of hourly
data is always resident in ControlWave GFC Plus
FLASH memory. The following items are stored in
the Hourly Data Log:
Corrected Volume
Uncorrected Volume
Accumulated Energy
Average Static Pressure
Average Temperature
Average Differential Pressure
The users interface to the Standard Ap-
plication Program is via a series of straight-
forward web style menu pages.
Overview of the Standard Application Program
Uses pre-congured web style menu pages for
user readings, conguration and maintenance—
PC menu pages can be modied and new
pages congured to work with a modied
application load
Uses the TechView Calibration Utility for
calibration of all transducers, including the
integral MVT and external, Bristol transmitters
(e.g., 3808 MVT)
The PC menu pages, calibration utility and
program load are all included on the BSI Cong
CD.
Standard conguration is a one-to-two run
station