Instruction manual
ControlWave Gas Flow Computer (GFC Plus) Instruction Manual (CI-ControlWave GFC Plus)
2-6 Installation Revised Feb-2013
(1) 1” Conduit Fitting - I/O wires (2) Local Port Connector
(3) RTD Cable Assembly or Sealing Plug (4) Battery Ventilation Assembly
(5) Solar Pwr. Cable, Ext. Pwr. Cable, or Plug (6) Ant. Cable, Polyphaser, or Plug
(7) Solderless Ground Lug (8) Multivariable Transducer
Figure 2-2. ControlWave GFC Plus Bottom View (Shown with MVT)
Units with Gage
Pressure Transducer
(GPT)
You can mount units with a GPT remotely to a panel, a wall, or to a
vertical 2 inch pipe clamped at the rear of the unit using the two
mounting brackets with two clamps and four bolts.
Caution
You cannot mount units with a GPT directly to the main (meter run).
Anchoring the Pipe
If you mount to a 2 inch pipe, you must anchor the pipe in cement deep
enough to conform to local building codes associated with frost
considerations.