Instruction Manual D5138 Part: D301687X012 March, 2011 ControlWave Radio-Ready Installation Guide For field installation of radios in: ControlWave Corrector ControlWave EFM ControlWave ExpressPAC ControlWave GFC ControlWave GFC Plus Remote Automation Solutions www.EmersonProcess.
IMPORTANT! READ INSTRUCTIONS BEFORE STARTING! Be sure that these instructions are carefully read and understood before any operation is attempted. Improper use of this device in some applications may result in damage or injury. The user is urged to keep this book filed in a convenient location for future reference. These instructions may not cover all details or variations in equipment or cover every possible situation to be met in connection with installation, operation or maintenance.
Emerson Process Management Training GET THE MOST FROM YOUR EMERSON INSTRUMENT OR SYSTEM Avoid Delays and problems in getting your system on-line Minimize installation, start-up and maintenance costs. Make the most effective use of our hardware and software. Know your system. As you know, a well-trained staff is essential to your operation. Emerson offers a full schedule of classes conducted by full-time, professional instructors.
This page is intentionally left blank
ControlWave Radio-Ready Installation Guide (D5138) Introduction You can order certain ControlWave-series devices with a radio preinstalled at the factory, or as “radio-ready” in which you can install a radio in the field.
ControlWave Radio-Ready Installation Guide (D5138) Radio Associated Installation Hardware Refer to these Figures 9710B & 9810 MDS 9710A Remote Data Transceiver (Radio) four (4) 6-32 x 5/16 mounting screws power cable radio interface cable Figure 16. ControlWave EFM Radio Installation - Mounting Diagram Figure 17. ControlWave EFM - Radio Mounting Bracket - Radio Installation Diagram Figure 1.
ControlWave Radio-Ready Installation Guide (D5138) Radio MDS iNET 900 Ethernet Radio Associated Installation Hardware radio interface cable four (4) 6-32 x 5/16 mounting screws power cable radio interface cable Refer to these Figures Figure 16. ControlWave EFM Radio Installation - Mounting Diagram Figure 17. ControlWave EFM - Radio Mounting Bracket - Radio Installation Diagram Figure 7.
ControlWave Radio-Ready Installation Guide (D5138) Installation WARNING Radios supplied by Emerson for use in the ControlWave Corrector, ControlWave ExpressPAC, ControlWave GFC, and ControlWave GFC Plus are approved for use in Class I, Division 2, Groups C, and D hazardous locations. Radios supplied by Emerson for use in the ControlWave EFM are approved for use in Class I, Division 2, Groups A, B, C, and D hazardous locations. Radios may also be used in nonhazardous locations.
ControlWave Radio-Ready Installation Guide (D5138) TB1-5 = Aux. Power Out+ (Red), TB1-6 = GND (Black). 8. For MDS radios, remove the MDS radio’s power connector from the radio, and connect the unterminated ends of the MDS power cable to the MDS power connector (Red = Pos., and Black = GND). Plug the end of the MDS radio power cable that you just dressed into the MDS radio.
ControlWave Radio-Ready Installation Guide (D5138) Figure 2.
ControlWave Radio-Ready Installation Guide (D5138) + FRONT VIEW (Mounted) LEFT SIDE VIEW RIGHT SIDE VIEW (Mounted) MDS Transnet TOP VIEW Figure 3.
ControlWave Radio-Ready Installation Guide (D5138) Figure 4.
ControlWave Radio-Ready Installation Guide (D5138) + FRONT VIEW (Mounted) LEFT SIDE VIEW RIGHT SIDE VIEW (Mounted) MDS entraNET 900 TOP VIEW Figure 5.
ControlWave Radio-Ready Installation Guide (D5138) Figure 6.
ControlWave Radio-Ready Installation Guide (D5138) + MDS entraNET 900 Access Point Radio FRONT VIEW (Mounted) LEFT SIDE VIEW RIGHT SIDE VIEW (Mounted) MDS iNET 900 Radios BOTTOM VIEW FRONT VIEW (Mounted) Figure 7.
ControlWave Radio-Ready Installation Guide (D5138) Figure 8.
ControlWave Radio-Ready Installation Guide (D5138) Figure 9.
ControlWave Radio-Ready Installation Guide (D5138) FRONT VIEW (Mounted) FreeWave RIGHT SIDE VIEW (Mounted) TOP VIEW Figure 10.
ControlWave Radio-Ready Installation Guide (D5138) Figure 11.
ControlWave Radio-Ready Installation Guide (D5138) Figure 12. Partial View – ControlWave GFC, EPAC, with/without Polyphaser Figure 13.
ControlWave Radio-Ready Installation Guide (D5138) Figure 14. Partial View - ControlWave Corrector with/without Polyphaser Figure 15.
ControlWave Radio-Ready Installation Guide (D5138) FRONT VIEW SIDE VIEW A A A Models: 4710A, 4710B, 9710A, 9710B & 9810 Two Screws that Secure the Radio Mounting Bracket to the Fabrication Panel.
ControlWave Radio-Ready Installation Guide (D5138) Figure 17. ControlWave EFM - Radio Mounting Bracket - Radio Installation Diagram Additional FreeWave Information The FreeWave Spread Spectrum Data Transceiver Model FGRM501X005 User Manual contains in-depth details on modem parameters, operation, installation, tuning transceiver performance, and more. Copies of the FreeWave Spread Spectrum Data Transceiver Model FGRM-501X005 User Manual can be obtained from FreeWave Technologies, Inc.
ControlWave Radio-Ready Installation Guide (D5138) Follow the “Tuning Transceiver Performance” section of the FreeWave Technologies, Inc. FreeWave Spread Spectrum Data Transceiver Model FGRM-501X005 User Manual to configure the radio. Note: Start HyperTerminal on your PC then invoke the setup program by connecting the radio to the PC. Set the parameters for that terminal to those of Table 2, and put the radio into setup mode.
ControlWave Radio-Ready Installation Guide (D5138) Figure 19.
ControlWave Radio-Ready Installation Guide Instruction Manual D5138 March, 2011 NOTICE Emerson Process Management Remote Automation Solutions 1100 Buckingham Street Watertown, CT 06795 Phone: +1 (860) 945-2262 Fax: +1 (860) 945-2525 www.EmersonProcess.com/Remote Emerson Process Management Remote Automation Solutions 6338 Viscount Rd. Mississauga, Ont. L4V 1H3 Canada Phone: 905-362-0880 Fax: 905-362-0882 www.EmersonProcess.com/Remote Emerson Process Management SA de CV Calle 10 #145 Col.