READ AND SAVE THESE INSTRUCTIONS LUXE ECO ™ 54” Ceiling Fan Owner's Manual Model Number CF550BS00 CF550ORB00 Net Weight: 20.9 Lbs. DATE CODE: The date code of this fan may be found on the box, stamped in ink on a white label. You should record this data above and keep it in a safe place for future use. Part No. F40BP74530001 Form No. BP7453-1 ETL Model No.
! WARNING WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel. 3.
Unpacking Instructions ! 2. Remove the lower styrofoam pad from the carton and place on a stable work surface. WARNING Do not install or use fan if any part is damaged or missing. Call Toll-Free: 3. Remove the fan motor assembly from the protective plastic bag and position the fan motor assembly in the lower styrofoam packing so that the top for the motor is facing you. Place all carton contents on a soft protective surface.
Electrical Requirements Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds. ! ! WARNING Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring.
How to Put Your Ceiling Fan Together (continued) 4. Make sure the rubber grommet is properly installed onto the coupling cover then slide the coupler cover onto the downrod until it rests on top of the motor housing. Place the ceiling cover over the downrod. Be sure both the ceiling cover and the coupler cover are oriented correctly (Figure 3). CEILING COVER 5. Route the motor leads through the hanger ball. Reinstall the hanger ball (Figure 4) on the downrod.
How to Hang Your Ceiling Fan ! CEILING WARNING Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock. ! AT LEAST 7' WARNING The fan must be hung with at least 7' of clearance from floor to blades (Figure 6).
How to Wire Your Ceiling Fan If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician. ! GROUND WIRE WARNING Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
Lower Light Kit Assembly 1. With the fan assembly safely installed on the mounting bracket, install the lower light kit as follows. 2. Remove one screw (retain for future use) and loosen the two other screws in the motor housing for installation of the light kit assembly (Figure 11). 3. Connect the white wire from the ceiling fan assembly to the white wire of the light kit assembly (Figure 11). Connect the black wire from the ceiling fan assembly to the black wire of the light kit assembly.
Wall Control Procedures General Preset Memory Feature Your Emerson Ceiling Fan/Light Control consists of wall mounted transmitter and a receiver which is preinstalled inside the motor assembly. The remote control is designed to separately control your ceiling fan speed and light intensity. Your Emerson receiver is equipped with a preset memory feature.
Wall Control Installation (continued) NOTE: Make all wiring connections using wire connectors (supplied). Make sure that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. SCREWS (2) FAN/LIGHT WALL CONTROL K BL HOT TO 120V AC SOURCE TO LOAD 1. Disconnect electrical power to the branch circuit at the circuit breaker or fuse box before attempting to install the ceiling fan wall control into the outlet box.
Wall Control Installation (continued) ! WARNING STANDARD WIRING FOR EXISTING 3-WAY CONTROLS Check to see that all connections are tight and that no bare wires are visible at the wire connectors. 6. Screw wall control into wall box using the supplied screws. Leave wall control in “OFF” mode until fan installation is completed. HOT EXISTING WALL CONTROL BLK BLACK 7. The wall control is supplied with a white, ivory, and almond color switch covers.
Programming the Receiver Operating Frequency & High Speed Conditioning of Fan Control IMPORTANT: Ceiling fan blades MUST be IMPORTANT: Do not interrupt the installed before high speed conditioning conditioning until the fan comes to a complete stop in approximately 5 minutes. can begin. 1. Within 1 minute of restoring electricity to the All functions of the control will be rejected ceiling fan, push and hold the fan OFF button ( ) during conditioning. for 3 to 5 seconds to set the code in the receiver.
Accessories 1. Ceiling Fan/Light Controls (see store or catalog). ! 2. Downrod Extension Kits (see store or catalog). ! WARNING This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
Repair Parts 4 2 1 7 3 19 13 8 9 12 14 20 6 10 5 11 18 15 16 17 14 ETL Model No.
Repair Parts Listing Key No. Model Number CF550ORB00 Description CF550BS00 761655-17 761655-32 1 2 3 Hanger Ball Assembly, Consisting of: Hanger Bracket Hanger Ball Downrod (4.5”) — — — — — — * 4 5 6 7 8 9 10 11 12 Parts Bag Containing: Wire Connector (5) Pin, Clevis (1) Clip, Hairpin (1) Threaded Stud, #8-32 x 1-1/4” (2) Lockwasher, External Tooth #8 (2) Knurled Knob, #8-32 (2) Screw, Flat Head Blade, #10-24 x .375” (21) Washer, Flat, #10 x .
Emerson Air Comfort Ceiling Fan Limited Warranty What The Limited Warranty Covers: This limited warranty is offered by Air Comfort Products division of Emerson Electric Co. ("Emerson" "we" or "us") located at the address stated below to the original retail purchaser ("you" or "your") of an Emerson Air Comfort Ceiling Fan product ("Emerson Ceiling Fan") and covers the motor and the other components and accessories of the Emerson Ceiling Fan against all defects in workmanship and materials.