BP7408 44" & 52" Curva 1/12/10 8:52 AM Page 1 READ AND SAVE THESE INSTRUCTIONS CURVA™ 44” & 52” Damp & Wet Location Ceiling Fan Owner's Manual 44” Model Numbers for Damp Locations 52” Model Numbers for Damp Locations CF244BS00 CF252BS00 Brushed Steel Brushed Steel CF244CRM00 CF252CRM00 Chrome Chrome 44” Model Numbers for Wet Locations 52” Model Numbers for Wet Locations CF244WW00 CF252WW00 Appliance White Appliance White CF244ORB00 CF252ORB00 Oil Rubbed Bronze Oil Rubbed Bronze Net
BP7408 44" & 52" Curva 1/12/10 8:52 AM ! Page 2 WARNING WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally.
BP7408 44" & 52" Curva 1/12/10 8:52 AM Page 3 THE FAN MODELS CF244BS, CF244CRM, CF252BS & CF252CRM ARE SUITABLE FOR DAMP LOCATIONS SUCH AS COVERED PORCHES, COVERED PATIOS, AND COVERED DECKS...ANYWHERE THERE IS A ROOF OVERHEAD. THE FAN MODELS CF244WW, CF244ORB, CF252WW & CF252ORB ARE SUITABLE FOR WET LOCATIONS SUCH AS PORCHES, PATIOS, AND DECKS.
BP7408 44" & 52" Curva 1/12/10 8:52 AM A. FAN MOTOR ASSEMBLY Page 4 B. CEILING COVER F. LIGHT KIT PLATE G. GLASS SHADE C. COUPLER COVER L. LOOSE PARTS BAG D. FAN BLADES (3) E. LOWER HOUSING H. NO-LIGHT COVER PLATE I. 6-SPEED ELECTRONIC RECEIVER J. 6-SPEED HANDHELD TRANSMITTER a. b. c. d. e. f. g. h. i.
BP7408 44" & 52" Curva 1/12/10 8:52 AM Electrical Requirements How to Assemble Your Ceiling Fan IMPORTANT: Your ceiling fan will not function properly, and may be damaged, if used with any wall dimmer switch or control other than the Emerson Electric Fan/Light Remote Control supplied with the fan. 1. Position the fan motor assembly upside down in preparation for mounting the three fan blades. 2. Slide blade through blade slot in fan housing assembly.
BP7408 44" & 52" Curva 1/12/10 8:52 AM 6. Remove and retain the wire connectors from the white and blue wires. 7. Connect the wire wire from the ceiling fan to the white wire of the light kit plate (Figure 3). Connect the blue wire from the ceiling fan to the black wire of the light kit plate. Use wire connectors (previously removed) to make connections. 8. Remove one of the three screws in the lower housing and loosen the remaining two screws (Figure 3). Page 6 11.
BP7408 44" & 52" Curva 1/12/10 8:52 AM Page 7 16. Reinstall the hanger ball (Figure 8) on the downrod as follows. Route the motor leads through the downrod. Position the pin through the two holes in the downrod and align the ball so the pin is captured in the groove in the top of the hanger ball. Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball. A loose setscrew could create fan wobble.
BP7408 44" & 52" Curva 1/12/10 8:52 AM How to Hang Your Ceiling Fan ! Page 8 ! WARNING Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock. WARNING The fan must be hung with at least 7' of clearance from floor to blades (Figure 9). CEILING 2.
BP7408 44" & 52" Curva 1/12/10 8:52 AM 1. Position the receiver into the ceiling cover as shown in Figure 12. Place the antenna wire on top of the receiver. NOTE: CEILING COVER, SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY. OUTLET BOX 2. Refer to Figures 12 and 13 to connect the receiver wires to the supply wires and the fan motor wires using the wire connectors supplied with the fan as follows: HANGER BRACKET a.
BP7408 44" & 52" Curva 1/12/10 8:52 AM Page 10 OUTLET BOX BLACK SUPPLY WIRE HANGER BRACKET BLACK FAN WIRE HANGER BRACKET GROUND WIRE (GREEN) BLACK/WHITE RECEIVER WIRE BLUE FAN WIRE HANGER BALL GROUND WIRE (GREEN) BLUE RECEIVER WIRE OPEN PORTION OF RECEIVER HERE SUPPLY GROUND WIRE (GREEN OR BARE) RECEIVER BLACK RECEIVER WIRE WHITE SUPPLY WIRE WHITE RECEIVER WIRE WHITE FAN WIRE CEILING COVER Figure 12 WIRE CONNECTOR 5.
BP7408 44" & 52" Curva 1/12/10 8:52 AM How to Assemble Your Light Kit Glass Shade Page 11 How to Assemble Your No Light Cover Plate 1. Screw in two 50-watt (maximum) halogen mini candelabra base bulbs in the light kit plate sockets (Figure 15). ! WARNING Do not install any light bulbs into the light kit plate if using the cover plate. Installation of light bulbs when using the cover plate could result in fire, shock and serious personal injury. 1.
BP7408 44" & 52" Curva 1/12/10 8:52 AM REMOTE CONTROL PROCEDURES Page 12 Installation of Battery 1. Remove the battery cover by pressing firmly below the arrow and sliding the cover off the control (Figure 18). General Your Emerson Ceiling Fan/Light Remote Control consists of hand-held transmitter and a receiver which is mounted under the fan ceiling cover. The remote control is designed to separately control your ceiling fan speed and light intensity.
BP7408 44" & 52" Curva 1/12/10 8:52 AM Page 13 Setting Operating Frequency of Remote Control Your remote control has code switches which must be set in one of 32 possible code combinations (Figure 18). The five levers (numbered 1, 2, 3, 4, and 5) on the switches are factory-set in the ON (up) position. Change the switch settings as follows (Figure 20): 1. Slide the five switch levers in the remote control to your choice of ON (up) or down positions.
BP7408 44" & 52" Curva 1/12/10 8:52 AM Maintenance Remote Control Trouble Shooting IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Fan/Light Fails to Operate • Check that the speed switch on the fan is set to HIGH (....) speed. • Check that the light switch is on. • Check that the battery is good (red indicator light should light when any button is pressed). • Check that the receiver is wired properly. • Check that code switches in the remote control and receiver are set in the same position.
BP7408 44" & 52" Curva 1/12/10 8:52 AM Page 15 WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX ! OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN. Ceiling Fan Trouble Shooting TROUBLE 1. Fan will not start. PROBABLE CAUSE 1. Fuse or circuit breaker blown. 2. Loose power line connections to the fan. 3. Fan/Light Remote Control is OFF. 2. Fan sounds noisy. 1. Blades not attached to fan. 2. Screws securing fan blades to motor are loose. SUGGESTED REMEDY 1.
BP7408 44" & 52" Curva 1/12/10 8:52 AM Page 16 Repair Parts Listing Damp Part Numbers Key Model No. Model No. No. Description CF244BS00 CF252BS00 Wet Part Numbers Model No. Model No. Model No. Model No. Model No. Model No.
BP7408 44" & 52" Curva 1/12/10 8:52 AM Page 17 Repair Parts 2 1 20 3 4 5 15 21 22 23 19 18 14 10 - 52" 11- 44" 16 13 6 17 12 7 9 8 Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER • PART DESCRIPTION • NAME OF ITEM • MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing. For repair parts, phone 1-800-654-3545.
BP7408 44" & 52" Curva 1/12/10 8:52 AM Page 18 INSTRUCTION TO THE USER (if device contains a digital device) This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
BP7408 44" & 52" Curva 1/12/10 8:52 AM Page 19 LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered. What The Period Of Coverage Is: As it applies to the motor, this warranty will last for the lifetime of your ceiling fan.
BP7408 44" & 52" Curva 1/12/10 8:52 AM Page 20 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 Part No. F40BP74080000 Printed in China 01/10 Form No. BP7408 UL Model No.