Brochure

Protecting Power System Availability
In Your Data Center
A regular preventive maintenance program from Emerson
Network Power is the best way to ensure maximum reliability of
data center equipment. Systematic inspection, detection and
correction of incipient failures keep infrastructure issues from
turning into costly downtime.
One study has shown that for a three-phase UPS system
(≥ 100 kVA), the Mean Time Between Failures for those units that
received two preventive maintenance visits a year is 23 times
higher than a system with no preventive service events in a year.
Our power preventive maintenance includes the following:
Repairing and reporting of all high temperature areas that may
affect component and unit performance.
Complete visual inspection of the equipment including
subassemblies, wire harnesses, contacts, cables, major
components and air filters.
Checking of inverter and rectifier boards, and checking all
mechanical connections for heat discoloration and tightness.
Replacement of swelled and leaking power capacitors and DC
capacitors with extruded vent caps.
SERVICES TO COMPLEMENT A REGULAR PREVENTIVE MAINTENANCE PROGRAM
Battery Replacement
Keep your power system running within specifications and minimize the risk of downtime
through proactive replacement of batteries by an expert who complies with all manufacturers’ and
IEEE standards.
Battery Service with
Ntegrated Monitoring
Use Albér monitoring technology to detect potential problems, and rapidly respond to defects and
degradation—improving overall system availability.
Battery Spares
Utilize fully charged on-site spares for minimal downtime and a more stable environment for your
business-critical power supply.
Capacitor Replacement
Extend the life of your UPS by proactively replacing the full bank of capacitors before an unexpected
failure occurs.
Power Assurance
Package
Safeguard your Liebert GXT or PSI systems and optimize the use of staff at your small IT site with
total maintenance and repair coverage for five years.
LIFE™ Services
Utilize technology embedded into your UPS and thermal equipment for continuous monitoring by
infrastructure specialists; data analysis by product and engineering experts; and corrective action by
highly trained customer engineers and field technicians.
Replacement of any life-limited components that may
have failed or show signs of failure.
Installation of all factory-recommended engineering field
change notices as necessary.
Inspection maintenance of individual batteries including
on-site and remote preventive maintenance options
utilizing Albér battery monitors.
Customer engineer consultation and system
recommendations.
Preventive Maintenance Directly Affects
Your Critical System Availability
Number of Annual Preventive Maintenance Visits
0 1 2 3 4
0
20
40
60
80
100
1x
23x
37x
51x
2.3x
1.6x
1.4x
10x