User Guide

64.....Avocent® Universal Management Gateway Appliance Installer/User Guide
Parameter Description
interval.
Default: Normal.
DTR Off Interval
Interval used by DTR Mode Off Interval in milliseconds.
Default: 100.
Line Feed Suppression
Enables the suppression of the LF character after the CR character.
Default: Disabled.
Null After CR
Suppression
Enables the suppression of the NULL character after the CR character.
Default: Disabled.
Transmission Interval
The interval the port waits to send data to a remote client in milliseconds.
Default: 20.
Break Sequence
Sequence used to send a break signal to the serial port. Not available for Raw.
Default: ~break.
Break Interval
Interval for the break signal in milliseconds. Not available for Raw.
Default: 500.
Log In/Out Multi
Session Notification
Enables the notification to multi-session users when a new user logs in or a user logs
out. Not available for Raw.
Default: Disabled.
Enable Auto Answer
When the input data matches one input string configured in Auto Answer, the output
string will be transmitted to the serial port.
Default: Disabled.
Enable Auto Discovery
The target name will be discovered based on the console or login prompt and will be
associated with this serial port.
Default: Disabled.
Enable Auto Speed
Detection
The speed of the serial port will be discovered.
Default:Disabled.
Note:Additional configuration operations for Auto Discovery and Speed Auto Detection are found on the
CASProfile tab.
Data Buffering
Port The number of the port.
Status
Enables or disables data buffering.
Default: Disabled.
Type
Displays the type of data buffering: Local - stores the data buffering file in the local
file system. Syslog - sends the data to the syslog server facility 0 with severity info.
Default: Local.
Time Stamp
When enabled, adds the time stamp to the data line for local data buffering.
Default: Disabled.
Log-in/out Message
Includes special notification for logins and logouts in data buffering.
Default: Disabled.
Serial Session Logging
Enabled - stores data at all times. Disabled - stores data when a remote serial
session is not opened.
Default: Disabled.
Alerts
Alert Strings
Regular expression or ASCII patterns used to generate event notifications. The
appliance will try to match the data received from a serial target with the configured
patterns. When there is a match, an alert is sent.
Default: Empty.