User Guide
18.....Avocent® Universal Management Gateway Appliance Installer/User Guide
Number Description Number Description
2 Ethernet connection 12 Remote authentication
3 User 13 PCclient
4 External sensors connection 14 USB media
5
Autosensing ports for serial or service
processor targets
15 RJ-45 serial setup port
6 UMIQ modulefor KVMconnection 16 DB9 com port
7 Target server (VGA/USB) 17 PCfor local configuration
8 Firewall 18
USBconnection (keyboard, mouse
or media)
9 Ethernet connection 19 VGAconsole port
10 Local Area Network (LAN) 20
LCDtray for local configuration
and access
Using Telnet or SSH to access a serial target
An authorized user can use a Telnet or SSH client to make a connection directly to the console of a
serial target if all of the following are true.
The Telnet or SSH:
• protocol is enabled for network service in the security profile
• protocol is configured for the port
• client is available, and it is enabled on the computer from which the connection is made
To use Telnet to connect to a target through a serial port:
For this procedure, you need the username configured to access the serial port, the target name
(for example, 14-35-60-p-1), device name (for example, ttyS1), TCP port alias (for example, 7001)
and the hostname of the appliance or its IP address.
To use a Telnet client, enter the information in the dialog boxes of the client.
-or-
To use Telnet in a shell, enter the following command:
# telnet [hostname | IP_address]
login: [username]:[targetname | device_name]
-or-
# telnet [hostname | IP_address] TCP_Port_Alias
login: [username]
To close a Telnet session: